| Literature DB >> 17536524 |
Alejandro Badia1, Prakash Khanchandani.
Abstract
This report presents a method of arthroscopic repair of the peripheral triangular fibrocartilage tears by using ultrasonic suture welding technique, thus avoiding the need for traditional suture knots. This technique eliminates the potential causes of ulnar-sided wrist discomfort especially during the postoperative period. Twenty-three patients (9 women and 14 men; mean age, 35 years; range, 18-52 years) were operated during a 1-year period in 2001 for Palmer grade 1B triangular fibrocartilage complex tear and followed up for 17 months. At the final follow-up, the average wrist arc of motion was as follows: extension, 65 degrees; flexion, 56 degrees; supination, 80 degrees; pronation, 78 degrees; radial deviation, 12 degrees; and ulnar deviation, 25 degrees. Grip strength measured with a dynamometer (Jamar) averaged 81% of the contralateral side at the final evaluation (range, 53%-105%).Entities:
Mesh:
Year: 2007 PMID: 17536524 DOI: 10.1097/bth.0b013e3180336cec