Literature DB >> 17533854

Development of a Luminex based competitive immunoassay for 2,4,6-trinitrotoluene (TNT).

George P Anderson1, Jacqueline D Lamar, Paul T Charles.   

Abstract

Previously, a displacement immunoassay for 2,4,6-trinitrotoluene (TNT) was demonstrated using the Luminex 100. The work presented utilized this same specialized flow cytometer to demonstrate a highly sensitive and rapid competitive immunoassay for TNT. This required a TNT analog to be attached to the microsphere surface. Various linkers were evaluated; bovine serum albumin provided over 3 times more binding sites in comparison to various shorter diamine linkers. For this assay TNB-coated microspheres were added to samples; then biotinylated anti-TNT antibody and the reporter molecule, Streptavidin-R-Phycoerythrin, were added. In the absence of TNT, a highly fluorescent complex was formed on the surface of the microsphere. The presence of TNT resulted in dose-dependent decreased fluorescence. Various anti-TNT antibodies were evaluated; Mab 30-1 gave the strongest response, yielding the lowest limit of detection (<1.0 ng/mL) and a dynamic range up to 1 microg/mL. Other factors such as reaction time, cross reactivity to other nitro-compounds, evaluation of acetone extracts of TNT contaminated soils, testing in environmental matrices such as fresh water and seawater were all completed. Finally, a multiplex assay for TNT and three protein toxins was successfully conducted using the competitive format.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17533854     DOI: 10.1021/es062333n

Source DB:  PubMed          Journal:  Environ Sci Technol        ISSN: 0013-936X            Impact factor:   9.028


  6 in total

1.  Multi-wavelength microflow cytometer using groove-generated sheath flow.

Authors:  Joel P Golden; Jason S Kim; Jeffrey S Erickson; Lisa R Hilliard; Peter B Howell; George P Anderson; Mansoor Nasir; Frances S Ligler
Journal:  Lab Chip       Date:  2009-03-31       Impact factor: 6.799

2.  Detection of fumonisin b1 and ochratoxin a in grain products using microsphere-based fluid array immunoassays.

Authors:  George P Anderson; Vasudha A Kowtha; Chris R Taitt
Journal:  Toxins (Basel)       Date:  2010-02-25       Impact factor: 4.546

3.  Fluorescence-based sensing of 2,4,6-trinitrotoluene (TNT) using a multi-channeled poly(methyl methacrylate) (PMMA) microimmunosensor.

Authors:  Paul T Charles; Andre A Adams; Peter B Howell; Scott A Trammell; Jeffrey R Deschamps; Anne W Kusterbeck
Journal:  Sensors (Basel)       Date:  2010-01-22       Impact factor: 3.576

4.  Fluorescent enzyme-linked immunosorbent assay based on alkaline phosphatase-responsive coordination polymer composite.

Authors:  Shenghua Li; Xing Hu; Yong Li; Hongliang Tan
Journal:  Mikrochim Acta       Date:  2021-07-21       Impact factor: 5.833

5.  Development of a five-plex flow cytometric immunoassay for the simultaneous detection of six coccidiostats in feed and eggs.

Authors:  Monique E Bienenmann-Ploum; Anne-Catherine Huet; Katrina Campbell; Terence L Fodey; Ursula Vincent; Willem Haasnoot; Philippe Delahaut; Christopher T Elliott; Michel W F Nielen
Journal:  Anal Bioanal Chem       Date:  2012-08-01       Impact factor: 4.142

6.  Fast Detection of 2,4,6-Trinitrotoluene (TNT) at ppt Level by a Laser-Induced Immunofluorometric Biosensor.

Authors:  Martin Paul; Georg Tscheuschner; Stefan Herrmann; Michael G Weller
Journal:  Biosensors (Basel)       Date:  2020-08-05
  6 in total