Literature DB >> 17532538

A virtual bronchoscopic navigation system under X-ray fluoroscopy for transbronchial diagnosis of small peripheral pulmonary lesions.

Motoko Tachihara1, Takashi Ishida, Kenya Kanazawa, Aya Sugawara, Kana Watanabe, Kumi Uekita, Hiroshi Moriya, Koichi Yamazaki, Fumihiro Asano, Mitsuru Munakata.   

Abstract

We had reported the utility of virtual bronchoscopic navigation system under CT-guidance for the diagnosis of small peripheral pulmonary lesions (PPLs). This study investigated the efficacy of virtual bronchoscopic navigation system for the diagnosis of small PPLs under X-ray fluoroscopy. We performed bronchoscopy with this system for 94 consecutive patients with 96 PPLs (< or =30mm in longest diameter; mean longest diameter, 16.2mm). A standard bronchoscope was used in 38 cases, and an ultrathin bronchoscope in 58 cases. Virtual bronchoscopic images were reconstructed from helical CT data. All the examinations were performed under X-ray fluoroscopy with virtual bronchoscopic navigation system, we referred both virtual bronchoscopic images and actual bronchoscopic images simultaneously to navigate the bronchoscopic pathway to the PPLs. Specimens for pathological examination were collected by transbronchial biopsy (TBB) and/or brushing. Virtual images accorded well with actual bronchoscopic images. The average total examination time was 24.1+/-7.4min (mean+/-S.D.). The overall diagnostic yields were 62.5% (60 of 96 PPLs), 71.1% (27 of 38 PPLs) with the standard bronchoscope, and 56.9% (33 of 58 PPLs) with the ultrathin bronchoscope. Diagnostic rates were 35%, 61.4% and 94.7% for lesions < or =10, 10-20, and >20mm, respectively. There were eight ground glass opacity (GGO) lesions confirmed only on CT scans; seven cases were pathologically diagnosed. All the examinations were performed safely with no complications. Bronchoscopy with virtual bronchoscopic navigation under X-ray fluoroscopy is useful for the diagnosis of small PPLs.

Entities:  

Mesh:

Year:  2007        PMID: 17532538     DOI: 10.1016/j.lungcan.2007.04.006

Source DB:  PubMed          Journal:  Lung Cancer        ISSN: 0169-5002            Impact factor:   5.705


  18 in total

1.  Meta-analysis of guided bronchoscopy for the evaluation of the pulmonary nodule.

Authors:  Jessica S Wang Memoli; Paul J Nietert; Gerard A Silvestri
Journal:  Chest       Date:  2012-08       Impact factor: 9.410

2.  Feasibility of respiratory motion-compensated stereoscopic X-ray tracking for bronchoscopy.

Authors:  Nikolas Leßmann; Daniel Drömann; Alexander Schlaefer
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-07-26       Impact factor: 2.924

3.  Bronchoscopy Using Virtual Navigation and Endobronchial Ultrasonography with a Guide Sheath (EBUS-GS) with or without Fluoroscopy for Peripheral Pulmonary Lesions.

Authors:  Motoko Tachihara; Daisuke Tamura; Tatsunori Kiriu; Shuntaro Tokunaga; Yukihisa Hatakeyama; Haruko Shinke; Tatsuya Nagano; Kyosuke Nakata; Nobuko Hazeki; Hiroshi Kamiryo; Kazuyuki Kobayashi; Yoshihiro Nishimura
Journal:  Kobe J Med Sci       Date:  2018-03-27

4.  Hybrid electromagnetic and image-based tracking of endoscopes with guaranteed smooth output.

Authors:  Tobias Reichl; Xiongbiao Luo; Manuela Menzel; Hubert Hautmann; Kensaku Mori; Nassir Navab
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-03-31       Impact factor: 2.924

5.  Shifted focus of bronchoalveolar lavage in patients with suspected thoracic malignancy: an analysis of 224 patients.

Authors:  Xin Zhang; Yukun Kuang; Yuan Zhang; Kai He; Noah Lechtzin; Mingying Zeng; Rex C Yung; Canmao Xie
Journal:  J Thorac Dis       Date:  2016-11       Impact factor: 2.895

6.  Combination of virtual bronchoscopic navigation, endobronchial ultrasound, and rapid on-site evaluation for diagnosing small peripheral pulmonary lesions: a prospective phase II study.

Authors:  Toshiya Maekura; Chikatoshi Sugimoto; Akihiro Tamiya; Nobuhiko Saijo; Yoko Naoki; Taro Koba; Yohei Kimura; Yoshinobu Matsuda; Masaki Kanazu; Naoko Takeuchi; Yumiko Sasaki; Yujiro Naito; Taisuke Tsuji; Reiko Sugawara; Takehiko Kobayashi; Keiko Nakao; Yoshihiko Taniguchi; Kyoichi Okishio; Naoki Omachi; Takahiko Kasai; Shinji Atagi
Journal:  J Thorac Dis       Date:  2017-07       Impact factor: 2.895

Review 7.  Advanced imaging (positron emission tomography and magnetic resonance imaging) and image-guided biopsy in initial staging and monitoring of therapy of lung cancer.

Authors:  Shaheen Islam; Ronald C Walker
Journal:  Cancer J       Date:  2013 May-Jun       Impact factor: 3.360

8.  Endobronchial ultrasound-guided transbronchial needle aspiration for the diagnosis of central lung parenchymal lesions.

Authors:  Akash Verma; Kyeongman Jeon; Won-Jung Koh; Gee Young Suh; Man Pyo Chung; Hojoong Kim; O Jung Kwon; Sang-Won Um
Journal:  Yonsei Med J       Date:  2013-05-01       Impact factor: 2.759

9.  Virtual bronchoscopic navigation combined with endobronchial ultrasound to diagnose small peripheral pulmonary lesions: a randomised trial.

Authors:  Takashi Ishida; Fumihiro Asano; Koichi Yamazaki; Naofumi Shinagawa; Satoshi Oizumi; Hiroshi Moriya; Mitsuru Munakata; Masaharu Nishimura
Journal:  Thorax       Date:  2011-07-11       Impact factor: 9.139

10.  Usefulness of computed tomography virtual bronchoscopy in the evaluation of bronchi divisions.

Authors:  Michał Adamczyk; Grzegorz Tomaszewski; Patrycja Naumczyk; Ewa Kluczewska; Jerzy Walecki
Journal:  Pol J Radiol       Date:  2013-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.