Literature DB >> 17531399

Setup variations in radiotherapy of esophageal cancer: evaluation by daily megavoltage computed tomographic localization.

Yi-Jen Chen1, Chunhui Han, An Liu, Timothy E Schultheiss, Kemp H Kernstine, Stephen Shibata, Nayana L Vora, Richard D Pezner, Jeffrey Y C Wong.   

Abstract

PURPOSE: To use pretreatment megavoltage computed tomography (MVCT) scans to evaluate setup variations in anterior-posterior (AP), lateral, and superior-inferior (SI) directions and rotational variations, including pitch, roll, and yaw, for esophageal cancer patients treated with helical tomotherapy. METHODS AND MATERIALS: Ten patients with locally advanced esophageal cancer treated by combined chemoradiation using helical tomotherapy were selected. After patients were positioned using their skin tattoos/marks, MVCT scans were performed before every treatment and automatically registered to planning kilovoltage CT scans according to bony landmarks. Image registration data were used to adjust patient setups before treatment. A total of 250 MVCT scans were analyzed. Correlations between setup variations and body habitus, including height, weight, relative weight change, body surface area, and patient age, were evaluated.
RESULTS: The standard deviations for systematic setup corrections in AP, lateral, and SI directions and pitch, roll, and yaw rotations were 1.5, 3.7, and 4.8 mm and 0.5 degrees, 1.2 degrees, and 0.8 degrees, respectively. The appropriate averages of random setup variations in AP, lateral, and SI directions and pitch, roll, and yaw rotations were 2.9, 5.2, and 4.4 mm, and 1.0 degrees, 1.2 degrees, and 1.1 degrees, respectively. Setup variations were stable throughout the entire course of radiotherapy in all three translational and three rotational displacements, with little change in magnitude. No significant correlations were found between setup variations and body habitus variables.
CONCLUSIONS: Daily MVCT scans before each treatment can effectively detect setup errors and thereby reduce planning target volume (PTV) margins. This will reduce radiation dose to critical organs and may translate into lower treatment-related toxicities.

Entities:  

Mesh:

Year:  2007        PMID: 17531399     DOI: 10.1016/j.ijrobp.2007.04.023

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  14 in total

Review 1.  Technological advances in radiotherapy for esophageal cancer.

Authors:  Milan Vosmik; Jiri Petera; Igor Sirak; Miroslav Hodek; Petr Paluska; Jiri Dolezal; Marcela Kopacova
Journal:  World J Gastroenterol       Date:  2010-11-28       Impact factor: 5.742

2.  Total body irradiation of bone marrow transplant using helical TomoTherapy with a focus on the quality of dose contribution at junction target volumes.

Authors:  N V N Madhusudhana Sresty; Deleep Gudipudi; A Krishnam Raju; T Anil Kumar; V R P Lakshmi; G Srikanth; M Narasimha
Journal:  Strahlenther Onkol       Date:  2021-04-14       Impact factor: 3.621

3.  Image-guided Radiotherapy Of Esophageal Cancer By Helical Tomotherapy: Acute Toxicity And Preliminary Clinical Outcome.

Authors:  Yi-Jen Chen; Kemp H Kernstine; Stephen Shibata; Dean Lim; David D Smith; Martin Tang; An Liu; Richard D Pezner; Jeffrey Y C Wong
Journal:  J Thorac Dis       Date:  2009-12       Impact factor: 2.895

4.  Volumetric modulated arc therapy planning for distal oesophageal malignancies.

Authors:  M A Hawkins; J L Bedford; A P Warrington; D M Tait
Journal:  Br J Radiol       Date:  2011-03-22       Impact factor: 3.039

5.  Simultaneous modulated accelerated radiation therapy for esophageal cancer: a feasibility study.

Authors:  Wu-Zhe Zhang; Jian-Zhou Chen; De-Rui Li; Zhi-Jian Chen; Hong Guo; Ting-Ting Zhuang; Dong-Sheng Li; Ming-Zhen Zhou; Chuang-Zhen Chen
Journal:  World J Gastroenterol       Date:  2014-10-14       Impact factor: 5.742

6.  Principles of modern radiation techniques for esophageal and gastroesophageal junction cancers.

Authors:  Gary Y Yang; Susan A McClosky; Nikhil I Khushalani
Journal:  Gastrointest Cancer Res       Date:  2009-03

7.  Comparison of setup accuracy of three different image assessment methods for tangential breast radiotherapy.

Authors:  Vikneswary Batumalai; Penny Phan; Callie Choong; Lois Holloway; Geoff P Delaney
Journal:  J Med Radiat Sci       Date:  2016-05-31

8.  A comparison of the dosimetric effects of intrafraction motion on step-and-shoot, compensator, and helical tomotherapy-based IMRT.

Authors:  Ben J Waghorn; Robert J Staton; Justin M Rineer; Sanford L Meeks; Katja Langen
Journal:  J Appl Clin Med Phys       Date:  2013-05-06       Impact factor: 2.102

9.  Correlation of primary middle and distal esophageal cancers motion with surrounding tissues using four-dimensional computed tomography.

Authors:  Wei Wang; Jianbin Li; Yingjie Zhang; Qian Shao; Min Xu; Bing Guo; Dongping Shang
Journal:  Onco Targets Ther       Date:  2016-06-22       Impact factor: 4.147

10.  A retrospective tomotherapy image-guidance study: analysis of more than 9,000 MVCT scans for ten different tumor sites.

Authors:  Patricia Sánchez-Rubio; Ruth Rodríguez-Romero; Pablo Castro-Tejero
Journal:  J Appl Clin Med Phys       Date:  2014-11-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.