Literature DB >> 17530976

Validation of an optical encoder during free weight resistance movements and analysis of bench press sticking point power during fatigue.

Eric J Drinkwater1, Brook Galna, Michael J McKenna, Patrick H Hunt, David B Pyne.   

Abstract

During the concentric movement of the bench press, there is an initial high-power push after chest contact, immediately followed by a characteristic area of low power, the so-called "sticking region." During high-intensity lifting, a decline in power can result in a failed lift attempt. The purpose of this study was to determine the validity of an optical encoder to measure power and then employ this device to determine power changes during the initial acceleration and sticking region during fatiguing repeated bench press training. Twelve subjects performed a free weight bench press, a Smith Machine back squat, and a Smith Machine 40-kg bench press throw for power validation measures. All barbell movements were simultaneously monitored using cinematography and an optical encoder. Eccentric and concentric mean and peak power were calculated using time and position data derived from each method. Validity of power measures between the video (criterion) and optical encoder scores were evaluated by standard error of the estimate (SEE) and coefficient of variation (CV). Seven subjects then performed 4 sets of 6 free weight bench press repetitions progressively increasing from 85 to 95% of their 6 repetition maximum, with each repetition continually monitored by an optical encoder. The SEE for power ranged from 3.6 to 14.4 W (CV, 1.0-3.0%; correlation, 0.97-1.00). During the free weight bench press training, peak power declined by approximately 55% (p < 0.01) during the initial acceleration phase of the final 2 repetitions of the final set. Although decreases in power of the sticking point were significant (p < 0.01), as early as repetition 5 (-40%) they reached critically low levels in the final 2 repetitions (>-95%). In conclusion, the optical encoder provided valid measures of kinetics during free weight resistance training movements. The decline in power during the initial acceleration phase appears a factor in a failed lift attempt at the sticking point.

Entities:  

Mesh:

Year:  2007        PMID: 17530976     DOI: 10.1519/R-20406.1

Source DB:  PubMed          Journal:  J Strength Cond Res        ISSN: 1064-8011            Impact factor:   3.775


  17 in total

1.  A mathematical model of neuromuscular adaptation to resistance training and its application in a computer simulation of accommodating loads.

Authors:  Ognjen Arandjelović
Journal:  Eur J Appl Physiol       Date:  2010-06-11       Impact factor: 3.078

2.  Prior sprint cycling did not enhance training adaptation, but resting salivary hormones were related to workout power and strength.

Authors:  Blair T Crewther; Tim Lowe; Robert P Weatherby; Nicholas Gill
Journal:  Eur J Appl Physiol       Date:  2009-01-14       Impact factor: 3.078

3.  A low-cost contact system to assess load displacement velocity in a resistance training machine.

Authors:  Bernat Buscà; Anna Font
Journal:  J Sports Sci Med       Date:  2011-09-01       Impact factor: 2.988

4.  Reliability and validity assessment of a linear position transducer.

Authors:  Manuel V Garnacho-Castaño; Silvia López-Lastra; José L Maté-Muñoz
Journal:  J Sports Sci Med       Date:  2015-03-01       Impact factor: 2.988

5.  Variable resistance training using elastic bands to enhance lower extremity strengthening.

Authors:  Daniel S Lorenz
Journal:  Int J Sports Phys Ther       Date:  2014-05

Review 6.  A brief review of strength and ballistic assessment methodologies in sport.

Authors:  Daniel Travis McMaster; Nicholas Gill; John Cronin; Michael McGuigan
Journal:  Sports Med       Date:  2014-05       Impact factor: 11.136

7.  The Validity and Reliability of Commercially Available Resistance Training Monitoring Devices: A Systematic Review.

Authors:  Jonathon Weakley; Matthew Morrison; Amador García-Ramos; Rich Johnston; Lachlan James; Michael H Cole
Journal:  Sports Med       Date:  2021-01-21       Impact factor: 11.136

Review 8.  Understanding and Overcoming the Sticking Point in Resistance Exercise.

Authors:  Justin Kompf; Ognjen Arandjelović
Journal:  Sports Med       Date:  2016-06       Impact factor: 11.136

9.  Relationships between Mechanical Variables in the Traditional and Close-Grip Bench Press.

Authors:  Robert G Lockie; Samuel J Callaghan; Matthew R Moreno; Fabrice G Risso; Tricia M Liu; Alyssa A Stage; Samantha A Birmingham-Babauta; John J Stokes; Dominic V Giuliano; Adrina Lazar; DeShaun L Davis; Ashley J Orjalo
Journal:  J Hum Kinet       Date:  2017-12-28       Impact factor: 2.193

10.  Validity and reliability of simple measurement device to assess the velocity of the barbell during squats.

Authors:  Silvio Lorenzetti; Thomas Lamparter; Fabian Lüthy
Journal:  BMC Res Notes       Date:  2017-12-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.