Literature DB >> 1752589

Neurosurgical vascular complications associated with aneurysm clips evaluated by postmortem angiography.

P J Karhunen1.   

Abstract

Neurosurgical vascular complications were evaluated by postmortem angiography in a consecutive prospective series of 63 patients in Helsinki who suffered a fatal outcome following neurosurgery for ruptured intracranial aneurysm. Operative vascular complications were revealed in 28 (44%) of the cases. Massive intraoperative bleeding resulting from rupture of the aneurysm or adjacent major artery during dissection or clip application complicated the operation in 16 (25%) patients. Clip-induced obstruction of cerebral arteries was detected by angiography in seven cases (11%). In six of the patients an adjacent cerebral vessel was accidentally clipped. In one case a kinking of the clip had caused obstruction of the right anterior cerebellar artery with resulting frontal infarct. A combination of rupture of the internal carotid artery and accidental ligation of the left posterior cerebellar artery occurring simultaneously during the clipping of a ruptured basilar aneurysm was detected in one patient (2%). Other types of complication were revealed in four cases (6%): detachment of clip with re-bleeding; clipping of an uninvolved aneurysm instead of the ruptured one; displacement of the clip beneath the ruptured aneurysm. Operations on ruptured basilar artery aneurysm were significantly (P less than 0.01) more prone to complications. The results indicate that operative vascular complications play a significant role in the mortality of aneurysm patients. Post-mortem angiographic technique with contrast medium that vulcanizes at room temperature is particularly suitable for demonstration of the haemodynamic significance of clip-induced cerebrovascular accidental occlusions, and is the only method at autopsy to reveal an occlusion caused by a kinking of a properly placed aneurysm clip.

Entities:  

Mesh:

Year:  1991        PMID: 1752589     DOI: 10.1016/0379-0738(91)90202-t

Source DB:  PubMed          Journal:  Forensic Sci Int        ISSN: 0379-0738            Impact factor:   2.395


  6 in total

1.  The role of intraoperative micro-Doppler ultrasound in verifying proper clip placement in intracranial aneurysm surgery.

Authors:  Ioannis Siasios; Eftychia Z Kapsalaki; Kostas N Fountas
Journal:  Neuroradiology       Date:  2012-03-14       Impact factor: 2.804

2.  Integration of indocyanine green videoangiography with operative microscope: augmented reality for interactive assessment of vascular structures and blood flow.

Authors:  Nikolay L Martirosyan; Jesse Skoch; Jeffrey R Watson; G Michael Lemole; Marek Romanowski; Rein Anton
Journal:  Neurosurgery       Date:  2015-06       Impact factor: 4.654

3.  Intraoperative microvascular Doppler ultrasonography in cerebral aneurysm surgery.

Authors:  R Stendel; T Pietilä; A A Al Hassan; A Schilling; M Brock
Journal:  J Neurol Neurosurg Psychiatry       Date:  2000-01       Impact factor: 10.154

4.  Sudden fatal or non-operable bleeding from ruptured intracranial aneurysm. Evaluation by post-mortem angiography with vulcanising contrast medium.

Authors:  P J Karhunen; A Servo
Journal:  Int J Legal Med       Date:  1993       Impact factor: 2.686

5.  Emergency In Situ Bypass during Middle Cerebral Artery Aneurysm Surgery: Middle Cerebral Artery-Superficial Temporal Artery Interposition Graft-Middle Cerebral Artery Anastomosis.

Authors:  Jong-Myung Jung; Chang Wan Oh; Kyung Sun Song; Jae Seung Bang
Journal:  J Korean Neurosurg Soc       Date:  2012-05-31

6.  Investigation of medical intervention with fatal outcome: the impact of post-mortem CT and CT angiography.

Authors:  Axel Heinemann; Hermann Vogel; Martin Heller; Antonios Tzikas; Klaus Püschel
Journal:  Radiol Med       Date:  2015-08-19       Impact factor: 3.469

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.