Literature DB >> 17525813

"One-step" simplified electrochemical sensing of TATP based on its acid treatment.

Rodrigo A A Munoz1, Donglai Lu, Avi Cagan, Joseph Wang.   

Abstract

A fast, simple and sensitive electrochemical method for sensing peroxide-based explosives based on their acid treatment is reported. The method relies on the high electrocatalytic activity of Prussian-blue (PB)-modified electrodes towards the acid-generated hydrogen peroxide in the harsh acidic medium (down to pH 0.3) used for releasing hydrogen peroxide. Such effective operation of PB electrochemical sensors in strongly acidic media eliminates the need for an additional neutralization step required in analogous peroxidase-based assays (due to acid-induced enzyme deactivation processes). Factors affecting the efficiency of the acid pre-treatment of triacetone triperoxide (TATP) have been examined and optimized to allow its sensitive measurement down to the 50 ng level within 60 s. Chronoamperometric detection of microgram amounts of solid TATP, following a one-minute acid mixing and placing a 20 microL droplet onto a disposable PB-modified screen-printed electrode is illustrated. Similar results were obtained for the peroxide explosive hexamethylene triperoxide diamine (HMTD). By greatly simplifying the analytical procedure, such an acid-operated "artificial peroxidase" electrocatalytic transducer holds great promise for designing "one-step", user-friendly, miniaturized, cost-effective devices for field screening of peroxide explosives.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17525813     DOI: 10.1039/b701356f

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  3 in total

1.  Molecular simulations of adsorption of RDX and TATP on IRMOF-1(Be).

Authors:  Andrea Michalkova Scott; Tetyana Petrova; Khorgolkhuu Odbadrakh; Donald M Nicholson; Miguel Fuentes-Cabrera; James P Lewis; Frances C Hill; Jerzy Leszczynski
Journal:  J Mol Model       Date:  2012-01-21       Impact factor: 1.810

Review 2.  Electronic Tongue-A Tool for All Tastes?

Authors:  Marta Podrażka; Ewa Bączyńska; Magdalena Kundys; Paulina S Jeleń; Emilia Witkowska Nery
Journal:  Biosensors (Basel)       Date:  2017-12-31

3.  Amperometric sensing of hydrogen peroxide vapor for security screening.

Authors:  John Benedet; Donglai Lu; Karel Cizek; Jeff La Belle; Joseph Wang
Journal:  Anal Bioanal Chem       Date:  2009-04-24       Impact factor: 4.142

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.