Literature DB >> 17525062

A comparison of dose savings of lead and lightweight aprons for shielding of 99m-Technetium radiation.

Helen Warren-Forward1, Paul Cardew, Bradley Smith, Llewellyn Clack, Kym McWhirter, Stacey Johnson, Kimberly Wessel.   

Abstract

Nuclear medicine technologists (NMTs) have the highest effective doses of radiation among medical workers. With increase in the use of lightweight materials in diagnostic radiography, the aim was to compare the effectiveness of lead and lightweight aprons in shielding from 99m-Technetium ((99m)Tc) gamma rays. The doses received from a scattering phantom to the entrance, 9cm depth and exit of a phantom were measured with LiF:Mg, Cu, P thermoluminescent dosemeters (TLDs). Doses and spectra were assessed without no shielding, with 0.5-mm lead and lightweight aprons. The lead and lightweight aprons decreased entrance surface doses by 76 and 59%, respectively. The spectral analysis showed that the lightweight apron provided better dose reduction at energies <95 keV, though lead was 35% more efficient at higher energies. While lead apron demonstrated better shielding, the additional savings should be considered with the weight differential. It is concluded that the lightweight apron is suitable to be worn by NMTs interacting with patients injected with a (99m)Tc labelled radiopharmaceutical.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17525062     DOI: 10.1093/rpd/ncm176

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  5 in total

1.  An Investigation to Determine an Optimum Protective Garment Material in Nuclear Medicine.

Authors:  R Parvaresh; A Haghparast; K Khoshgard; M Jalili; M T Eivazi; M Ghorbani
Journal:  J Biomed Phys Eng       Date:  2018-12-01

2.  Application of a tungsten apron for occupational radiation exposure in nursing care of children with neuroblastoma during 131I-meta-iodo-benzyl-guanidine therapy.

Authors:  Yuka Taniguchi; Hiroshi Wakabayashi; Hiroto Yoneyama; Zhuoqing Chen; Kei Morino; Akiko Otosaki; Masako Yamada; Anri Inaki; Daiki Kayano; Seigo Kinuya
Journal:  Sci Rep       Date:  2022-01-07       Impact factor: 4.379

3.  Physical analysis of the shielding capacity for a lightweight apron designed for shielding low intensity scattering X-rays.

Authors:  Seon Chil Kim; Jeong Ryeol Choi; Byeong Kyou Jeon
Journal:  Sci Rep       Date:  2016-07-27       Impact factor: 4.379

4.  A Phantom Study on Fetal Dose Reducing Factors in Pregnant Patients with Breast Cancer during Radiotherapy Treatment.

Authors:  Akın Öğretici; Aydın Çakır; Uğur Akbaş; Canan Köksal; Ümmühan Kalafat; Makbule Tambaş; Hatice Bilge
Journal:  J Med Phys       Date:  2017 Jul-Sep

5.  A simple quality control tool for assessing integrity of lead equivalent aprons.

Authors:  Roshan S Livingstone; Anna Varghese
Journal:  Indian J Radiol Imaging       Date:  2018 Apr-Jun
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.