Neutron measurements in a Varian 2,100C LINAC facility using a Bonner sphere system based on passive gold activation detectors.

F Fernández1, C Domingo, K Amgarou, J Castelo, T Bouassoule, M J Garcia, E Luguera.   

Abstract

The use of high-energy linear electron accelerators (LINACs) for medical cancer treatments is widespread on an international scale. The associated bremsstrahlung X rays may produce neutrons as a result of subsequent photonuclear reactions with the different materials constituting the accelerator head. The generated neutron field is highly variable and depends strongly on the beam energy, on the accelerator shielding, on the flattering filter as well as on the movable collimators (jaws) design and on the irradiation field geometry. An estimate of this photoneutron component is, thus, of practical interest to quantify the radiological risk for the working staff and patients. Due to high frequency electromagnetic fields, and also to the presence of abundant leaked and scattered photons in these installations, measurements of the corresponding neutron fields by active dosemeters are extremely difficult. A modified version of the Bonner sphere system, based on passive gold activation detectors, has been used to perform neutron measurements at two points in a Varian 2,100C LINAC facility. A home-made unfolding procedure (CDM) has been utilised to determine the neutron spectra present at the measurement points. Results indicate that the giant dipole resonance process is the most adequate model to explain neutron production in the LINAC and that a thermal component is present at the measurement points.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17525060     DOI: 10.1093/rpd/ncm075

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  4 in total

Review 1.  A review on photoneutrons characteristics in radiation therapy with high-energy photon beams.

Authors:  Alireza Naseri; Asghar Mesbahi
Journal:  Rep Pract Oncol Radiother       Date:  2010-09-22

2.  Monte Carlo characterizations mapping of the (γ,n) and (n,γ) photonuclear reactions in the high energy X-ray radiation therapy.

Authors:  Hosein Ghiasi
Journal:  Rep Pract Oncol Radiother       Date:  2013-07-31

3.  Neutron dose measurements of Varian and Elekta linacs by TLD600 and TLD700 dosimeters and comparison with MCNP calculations.

Authors:  Hassan Ali Nedaie; Hoda Darestani; Nooshin Banaee; Negin Shagholi; Kheirollah Mohammadi; Arjang Shahvar; Esmaeel Bayat
Journal:  J Med Phys       Date:  2014-01

4.  Breakthrough whole body energy-specific and tissue-specific photoneutron dosimetry by novel miniature neutron dosimeter/spectrometer.

Authors:  Mehdi Sohrabi; Morteza Ebrahimzadeh Torkamani
Journal:  Sci Rep       Date:  2021-10-15       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.