Literature DB >> 17523087

An update on FIV and FeLV test performance using a Bayesian statistical approach.

Mark D G Pinches1, Gillian Diesel, Christopher R Helps, Séverine Tasker, Kathy Egan, Tim J Gruffydd-Jones.   

Abstract

BACKGROUND: Screening tests for feline retroviruses are thought to have high sensitivity and specificity, although previous studies that evaluated these tests have limitations. Novel statistical approaches have been developed that allow the estimation of sensitivity and specificity in situations where the true state of the disease in individual animals cannot be assured.
OBJECTIVE: The purpose of this study was to evaluate the sensitivity and specificity of a variety of retrovirus tests, including some screening tests, in a population of cats potentially infected with either feline leukemia virus (FeLV) and/or feline immunodeficiency virus (FIV) by using a Bayesian statistical approach.
METHODS: Four hundred and ninety blood samples from cats being evaluated for FIV infection were tested by 2 rapid immunomigration tests (Witness single [WS], Witness combi [WC]) and a plate-based ELISA (Petcheck) for FIV antibody, and by a newly designed real-time polymerase chain reaction (PCR) assay for FIV provirus. Four hundred and ninety-five blood samples from cats being evaluated for FeLV infection were tested by 2 rapid immunomigration tests (WS, WC) and a plate-based ELISA (Petcheck) for FeLV antigen, and by a FeLV virus isolation technique. Results were then analyzed by using a Bayesian statistical method.
RESULTS: For FIV tests, median sensitivity estimates were 0.98 for WS, 0.97 for WC, 0.98 for ELISA, and 0.92 for PCR. Median specificity estimates were 0.96 for WS, 0.96 for WC, 0.93 for ELISA, and 0.99 for PCR. For FeLV tests, median sensitivity estimates were 0.97 for WS, 0.97 for WC, 0.98 for ELISA, and 0.91 for virus isolation. Median specificity estimates were 0.96 for WS, 0.96 for WC, 0.98 for ELISA, and 0.99 for virus isolation.
CONCLUSIONS: The use of Bayesian statistical methods overcomes a variety of methodologic problems associated with diagnostic test evaluations, including the lack of a definitive reference test. The sensitivity and the specificity of all 6 evaluated screening tests was high: however, specificity estimates were slightly lower than those reported by most recent studies.

Entities:  

Mesh:

Year:  2007        PMID: 17523087     DOI: 10.1111/j.1939-165x.2007.tb00200.x

Source DB:  PubMed          Journal:  Vet Clin Pathol        ISSN: 0275-6382            Impact factor:   1.180


  3 in total

1.  Performance of 4 Point-of-Care Screening Tests for Feline Leukemia Virus and Feline Immunodeficiency Virus.

Authors:  J K Levy; P Cynda Crawford; S J Tucker
Journal:  J Vet Intern Med       Date:  2017-02-03       Impact factor: 3.333

2.  Prevalence and risk factor analysis for feline haemoplasmas in cats from Northern Serbia, with molecular subtyping of feline immunodeficiency virus.

Authors:  Elpida Sarvani; Séverine Tasker; Milica Kovacˇević Filipović; Jelena Francuski Andrić; Nenad Andrić; Larissa Aquino; Sarah English; Charalampos Attipa; Christian M Leutenegger; Chris R Helps; Kostas Papasouliotis
Journal:  JFMS Open Rep       Date:  2018-05-22

Review 3.  Feline leukaemia. ABCD guidelines on prevention and management.

Authors:  Hans Lutz; Diane Addie; Sándor Belák; Corine Boucraut-Baralon; Herman Egberink; Tadeusz Frymus; Tim Gruffydd-Jones; Katrin Hartmann; Margaret J Hosie; Albert Lloret; Fulvio Marsilio; Maria Grazia Pennisi; Alan D Radford; Etienne Thiry; Uwe Truyen; Marian C Horzinek
Journal:  J Feline Med Surg       Date:  2009-07       Impact factor: 2.015

  3 in total