Literature DB >> 17522946

Preoperative lymphoscintigraphy predicts the successful identification but is not necessary in sentinel lymph nodes biopsy in breast cancer.

Lei Wang1, Jin-ming Yu, Yong-sheng Wang, Wen-shu Zuo, Yan Gao, Jiang Fan, Ji-yu Li, Xu-dong Hu, Ming-lu Chen, Guo-ren Yang, Zheng-bo Zhou, Yan-song Liu, Yong-qing Li, Yan-bing Liu, Tong Zhao, Peng Chen.   

Abstract

BACKGROUND: Although preoperative lymphoscintigraphy in sentinel lymph node biopsy (SLNB) for breast cancer patients is undergone commonly, its clinical significance remains controversial.
METHODS: We retrospectively analyzed our database that contained 636 consecutive breast cancer patients who received preoperative lymphoscintigraphy before SLNB.
RESULTS: The sentinel lymph nodes (SLNs) of 86.5% of patients were well imaged by lymphoscintigraphy, and SLN were located extra-axilla in 5.3% patients. The visualization of SLN in lymphoscintigraphy was not associated with histopathologic type, location, and stage of primary tumor, as well as the time interval from injection of radiocolloid to surgery. The negative lymphoscintigraphy results were associated with excision ;biopsy before injection of radiocolloid and positive axillary node statues. The SLN was successfully detected in 625 (98.3%) enrolled patients. Failure of surgical identification of axillary SLN was associated with whether hot spot was imaged by lymphoscintigraphy. However, we identified axillary SLN in 90 (90.9%) out of 99 patients with negative axillary findings in lymphoscintigram. The false negative rate of SLNB in our study was 16.0% (15 of 94) among patients of training group, and there was no significant difference in the false negative rate between patients who had axillary hot spot in lymphoscintigram and those who had not (P = .273).
CONCLUSIONS: Visualization of SLN in preoperative lymphoscintigraphy predicted the successful SLN identification. However, it was less informative for the location of SLN during operation. Considering the complexity, time consumed, and cost, lymphoscintigraphy should at present be undergone for investigation purposes only.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17522946     DOI: 10.1245/s10434-007-9418-4

Source DB:  PubMed          Journal:  Ann Surg Oncol        ISSN: 1068-9265            Impact factor:   5.344


  15 in total

1.  Removal of all radioactive sentinel nodes in breast cancer improves the detection of positive sentinel nodes.

Authors:  I Rubio; F Pedreira; I Roca; A Cabaleiro; C Mendoza; O Córdoba; T Cortadellas; D Sabadell; J Xercavins
Journal:  Clin Transl Oncol       Date:  2008-06       Impact factor: 3.405

2.  The clinical value of hybrid sentinel lymphoscintigraphy to predict metastatic sentinel lymph nodes in breast cancer.

Authors:  Chang Ju Na; Jeonghun Kim; Sehun Choi; Yeon-Hee Han; Hwan-Jeong Jeong; Myung-Hee Sohn; Hyun Jo Youn; Seok Tae Lim
Journal:  Nucl Med Mol Imaging       Date:  2014-10-17

3.  Would Removal of All Ultrasound Abnormal Metastatic Lymph Nodes Without Sentinel Lymph Node Biopsy Be Accurate in Patients with Breast Cancer with Neoadjuvant Chemotherapy?

Authors:  Geok Hoon Lim; Mihir Gudi; Sze Yiun Teo; Ruey Pyng Ng; Zhiyan Yan; Yien Sien Lee; John C Allen; Lester Chee Hao Leong
Journal:  Oncologist       Date:  2020-07-07

4.  Breast cancer sentinel lymph node mapping using near-infrared guided indocyanine green in comparison with blue dye.

Authors:  Wenbin Guo; Li Zhang; Jun Ji; Wei Gao; Jintao Liu; Meng Tong
Journal:  Tumour Biol       Date:  2013-12-05

5.  Sentinel Lymph Node Detection Using Carbon Nanoparticles in Patients with Early Breast Cancer.

Authors:  Xiufeng Wu; Qingzhong Lin; Gang Chen; Jianping Lu; Yi Zeng; Xia Chen; Jun Yan
Journal:  PLoS One       Date:  2015-08-21       Impact factor: 3.240

6.  Evaluation of the benefit of using blue dye in addition to indocyanine green fluorescence for sentinel lymph node biopsy in patients with breast cancer.

Authors:  Wenbin Guo; Li Zhang; Jun Ji; Wei Gao; Jintao Liu; Meng Tong
Journal:  World J Surg Oncol       Date:  2014-09-20       Impact factor: 2.754

7.  Use of Fluorescence Imaging in Combination with Patent Blue Dye versus Patent Blue Dye Alone in Sentinel Lymph Node Biopsy in Breast Cancer.

Authors:  Meng Tong; Wenbin Guo; Wei Gao
Journal:  J Breast Cancer       Date:  2014-09-30       Impact factor: 3.588

8.  Validation of the Memorial Sloan Kettering Cancer Center nomogram for predicting non-sentinel lymph node metastasis in sentinel lymph node-positive breast-cancer patients.

Authors:  Xiang Bi; Yongsheng Wang; Minmin Li; Peng Chen; Zhengbo Zhou; Yanbing Liu; Tong Zhao; Zhaopeng Zhang; Chunjian Wang; Xiao Sun; Pengfei Qiu
Journal:  Onco Targets Ther       Date:  2015-02-23       Impact factor: 4.147

9.  Validation study for the hypothesis of internal mammary sentinel lymph node lymphatic drainage in breast cancer.

Authors:  Bin-Bin Cong; Peng-Fei Qiu; Yan-Bing Liu; Tong Zhao; Peng Chen; Xiao-Shan Cao; Chun-Jian Wang; Zhao-Peng Zhang; Xiao Sun; Jin-Ming Yu; Yong-Sheng Wang
Journal:  Oncotarget       Date:  2016-07-05

10.  Internal Mammary Sentinel Lymph Node Biopsy With Modified Injection Technique: High Visualization Rate and Accurate Staging.

Authors:  Peng-Fei Qiu; Bin-Bin Cong; Rong-Rong Zhao; Guo-Ren Yang; Yan-Bing Liu; Peng Chen; Yong-Sheng Wang
Journal:  Medicine (Baltimore)       Date:  2015-10       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.