Literature DB >> 17520734

TSE with average-specific phase encoding ordering for motion detection and artifact suppression.

Ling Zhang1, Eugene G Kholmovski, Junyu Guo, Dennis L Parker.   

Abstract

PURPOSE: To detect motion-corrupted measurements in multi-average turbo-spin-echo (TSE) acquisitions and reduce motion artifacts in reconstructed images.
MATERIALS AND METHODS: An average-specific phase encoding (PE) ordering scheme was developed for multi-average TSE sequences in which each echo train is assigned a unique PE pattern for each pre-averaged image (PAI). A motion detection algorithm is developed based on this new PE ordering to identify which echo trains in which PAIs are motion-corrupted. The detected PE views are discarded and replaced by uncorrupted k-space data of the nearest PAI. Both phantom and human studies were performed to investigate the effectiveness of motion artifact reduction using the proposed method.
RESULTS: Motion-corrupted echo trains were successfully detected in all phantom and human experiments. Significant motion artifact suppression has been achieved for most studies. The residual artifacts in the reconstructed images are mainly caused by residual inconsistencies that remain after the corrupted k-space data is corrected.
CONCLUSION: The proposed method combines a novel data acquisition scheme, a robust motion detection algorithm, and a simple motion correction algorithm. It is effective in reducing motion artifacts for images corrupted by either bulk motion or local motion that occasionally happens during data acquisition. (c) 2007 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2007        PMID: 17520734     DOI: 10.1002/jmri.20908

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  3 in total

1.  CINE turbo spin echo imaging.

Authors:  Jason Mendes; Dennis L Parker; Jordan Hulet; Gerald S Treiman; Seong-Eun Kim
Journal:  Magn Reson Med       Date:  2011-06-23       Impact factor: 4.668

2.  Reduction of respiratory ghosting motion artifacts in conventional two-dimensional multi-slice Cartesian turbo spin-echo: which k-space filling order is the best?

Authors:  Yuuji Inoue; Masami Yoneyama; Masanobu Nakamura; Atsushi Takemura
Journal:  Radiol Phys Technol       Date:  2018-03-07

3.  Comparison of mouse brain DTI maps using K-space average, image-space average, or no average approach.

Authors:  Shu-Wei Sun; Jennifer Mei; Keelan Tuel
Journal:  Magn Reson Imaging       Date:  2013-08-27       Impact factor: 2.546

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.