Literature DB >> 17520733

Contrast-to-noise ratio (CNR) as a quality parameter in fMRI.

Alexander Geissler1, Andreas Gartus, Thomas Foki, Amir Reza Tahamtan, Roland Beisteiner, Markus Barth.   

Abstract

PURPOSE: To evaluate the impact of data quality on the localization of brain activation in functional magnetic resonance imaging (fMRI) and to explore whether the temporal contrast-to-noise-ratio (CNR) provides a quantitative parameter to estimate fMRI quality.
MATERIALS AND METHODS: We investigated two methods for defining the CNR by comparing them on a single-run, single session, as well as on a group-wise basis. The CNRs of healthy subjects and a group of patients with brain lesions were calculated using two different strategies: one based on a general linear model (GLM) analysis (CNR_SPM), and one that acts as an adaptive low-pass filter and assumes that the high-frequency components contain the temporal noise (CNR_SG). Runs with low CNR were identified as outliers using a common exclusion criterion (2 x standard deviation (SD)).
RESULTS: The results of the two CNR methods are highly correlated. Both between and within subjects and patients the CNR showed quite large variations, but the average CNR did not differ between a group of healthy subjects and a patient group. In total, seven of 213 runs (3.3% of all runs) had to be excluded when CNR_SG was used, and 14 of 213 (6.6%) runs had to be excluded when CNR_SPM was used.
CONCLUSION: Calculating the CNR using an adaptive low-pass filter gives similar results to a GLM-based approach and could be advantageous for cases in which the hemodynamic response function (HRF) differs significantly from common assumptions. The CNR can be used to identify and exclude runs with suboptimal CNR, and to identify sessions with insufficient data quality. The CNR may serve as a quantitative and intuitive parameter to assess the performance and quality of clinical fMRI investigations, including information on both functional performance (contrast) and data quality (noise caused by the system and physiology). (c) 2007 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2007        PMID: 17520733     DOI: 10.1002/jmri.20935

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  20 in total

1.  Quantitative image quality evaluation of MR images using perceptual difference models.

Authors:  Jun Miao; Donglai Huo; David L Wilson
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

2.  Efavirenz is associated with altered fronto-striatal function in HIV+ adolescents.

Authors:  Stéfan Du Plessis; Alexander Perez; Jean-Paul Fouche; Nicole Phillips; John A Joska; Matthijs Vink; Landon Myer; Heather J Zar; Dan J Stein; Jacqueline Hoare
Journal:  J Neurovirol       Date:  2019-06-04       Impact factor: 2.643

3.  Optimized partial-coverage functional analysis pipeline (OPFAP): a semi-automated pipeline for skull stripping and co-registration of partial-coverage, ultra-high-field functional images.

Authors:  Peter E Yoo; Jon O Cleary; Scott C Kolbe; Roger J Ordidge; Terence J O'Brien; Nicholas L Opie; Sam E John; Thomas J Oxley; Bradford A Moffat
Journal:  MAGMA       Date:  2018-05-29       Impact factor: 2.310

4.  Enhanced phase regression with Savitzky-Golay filtering for high-resolution BOLD fMRI.

Authors:  Robert L Barry; John C Gore
Journal:  Hum Brain Mapp       Date:  2014-01-17       Impact factor: 5.038

5.  A nonlinear generalization of the Savitzky-Golay filter and the quantitative analysis of saccades.

Authors:  Weiwei Dai; Ivan Selesnick; John-Ross Rizzo; Janet Rucker; Todd Hudson
Journal:  J Vis       Date:  2017-08-01       Impact factor: 2.240

6.  High spatiotemporal vessel-specific hemodynamic mapping with multi-echo single-vessel fMRI.

Authors:  Yi He; Maosen Wang; Xin Yu
Journal:  J Cereb Blood Flow Metab       Date:  2019-11-07       Impact factor: 6.200

Review 7.  [Methodological problems with clinical functional MRI investigations].

Authors:  T Foki; R Beisteiner
Journal:  Radiologe       Date:  2010-02       Impact factor: 0.635

8.  Assessment of frame-averaging algorithms in OCT image analysis.

Authors:  Wei Wu; Ou Tan; Rajeev R Pappuru; Huilong Duan; David Huang
Journal:  Ophthalmic Surg Lasers Imaging Retina       Date:  2013 Mar-Apr       Impact factor: 1.300

9.  Clinical fMRI: evidence for a 7T benefit over 3T.

Authors:  R Beisteiner; S Robinson; M Wurnig; M Hilbert; K Merksa; J Rath; I Höllinger; N Klinger; Ch Marosi; S Trattnig; A Geissler
Journal:  Neuroimage       Date:  2011-05-17       Impact factor: 6.556

10.  TOMOBFLOW: feature-preserving noise filtering for electron tomography.

Authors:  Jose-Jesus Fernandez
Journal:  BMC Bioinformatics       Date:  2009-06-12       Impact factor: 3.169

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.