Evaluation of oxygen saturation monitoring by pulse oximetry in neonates in the delivery system.

I Dimich1, P P Singh, A Adell, M Hendler, N Sonnenklar, M Jhaveri.   

Abstract

The pulse oximeter was evaluated for use in neonates in the delivery room. One hundred neonates, delivered vaginally or by Caesarean section with general or epidural anaesthesia, were studied. After delivery, pulse oximetry probes were placed simultaneously on the ulnar side of the right hand and on the right Achilles tendon to determine whether there was a difference in arterial oxygenation (SpO2). Measurements of SpO2 were taken at 1, 5, 10 min, and 24 hr after delivery. At one and five minutes, SpO2 recorded from the right hand was higher than that recorded from the lower extremities (71.9% +/- 6.5% vs 63.4% +/- 4.3% and 83.3% +/- 4.2% vs 76% +/- 4.1%, mean +/- SD, respectively). At ten minutes these differences diminished, and had almost completely disappeared after 24 hr. These results can be explained by the presence of R-L shunting at the ductus arteriosus level, producing reduced SaO2 in the lower extremities. Oxygen saturation did not differ between neonates delivered vaginally or by Caesarean section, regardless of the presence or type of anaesthesia. We concluded that neonates remain relatively desaturated in the immediate postpartum period and that the SpO2 obtained from the right hand is a better index of neonatal oxygenation than that obtained from the heel.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1752021     DOI: 10.1007/BF03008616

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  7 in total

1.  Human fetal circulation: changes in the cardiovascular system at birth and disturbances in the post-natal closure of the foramen ovale and ductus arteriosus.

Authors:  J LIND; C WEGELIUS
Journal:  Cold Spring Harb Symp Quant Biol       Date:  1954

2.  The physiologic closure of the ductus arteriosus in newborn infants: a preliminary report.

Authors:  F L ELDRIDGE; H N HULTGREN; M E WIGMORE
Journal:  Science       Date:  1954-05-21       Impact factor: 47.728

3.  The patency of the ductus arteriosus after birth.

Authors:  G S DAWES; E D MILNE; J C MOTT; J G WIDDICOMBE
Journal:  J Physiol       Date:  1953       Impact factor: 5.182

4.  Changes in arterial oxygen saturation immediately after birth in the human neonate.

Authors:  A P Harris; M J Sendak; R T Donham
Journal:  J Pediatr       Date:  1986-07       Impact factor: 4.406

5.  Evaluation of pulse oximetry.

Authors:  M Yelderman; W New
Journal:  Anesthesiology       Date:  1983-10       Impact factor: 7.892

6.  Pulse oximetry in critically ill children.

Authors:  C D Fait; R C Wetzel; J M Dean; C L Schleien; F R Gioia
Journal:  J Clin Monit       Date:  1985-10

7.  Serial blood-gas tensions and acid-base balance during the first hour of life in human infants.

Authors:  T K OLIVER; J A DEMIS; G D BATES
Journal:  Acta Paediatr       Date:  1961-07       Impact factor: 2.299

  7 in total
  12 in total

1.  A comparison between two NIRS oximeters (INVOS, OxyPrem) using measurement on the arm of adults and head of infants after caesarean section.

Authors:  Simon Hyttel-Sorensen; Trine Witzner Hessel; Amalia la Cour; Gorm Greisen
Journal:  Biomed Opt Express       Date:  2014-09-18       Impact factor: 3.732

Review 2.  Pulse oximetry for monitoring infants in the delivery room: a review.

Authors:  J A Dawson; P G Davis; C P F O'Donnell; C O F Kamlin; C J Morley
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2007-01       Impact factor: 5.747

3.  Normal oxygen saturation trend in healthy term newborns within 30 minutes of birth.

Authors:  Ravikumar Hulsoore; Jyotsna Shrivastav; Rashmi Dwivedi
Journal:  Indian J Pediatr       Date:  2011-03-17       Impact factor: 1.967

4.  Reflectance pulse oximetry at the forehead of newborns: the influence of varying pressure on the probe.

Authors:  A C Dassel; R Graaff; A Meijer; W G Zijlstra; J G Aarnoudse
Journal:  J Clin Monit       Date:  1996-11

5.  Oxygen saturation during the first 24 hours of life.

Authors:  L M O'Brien; V A Stebbens; C F Poets; E G Heycock; D P Southall
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2000-07       Impact factor: 5.747

6.  Oxygen saturation profile in late-preterm and term infants: a prospective cohort study.

Authors:  P S Shah; H Hakak; A Mohamed; J Shah; J Young; E Kelly
Journal:  J Perinatol       Date:  2014-06-05       Impact factor: 2.521

7.  Oxygen saturation immediately after birth in infants delivered in tertiary care hospital in India.

Authors:  Manisha Bhandankar; Vishwanath D Patil; Dharmapuri Vidyasagar
Journal:  Indian J Pediatr       Date:  2013-07-04       Impact factor: 1.967

Review 8.  Oxygen saturation and heart rate in healthy term and late preterm infants with delayed cord clamping.

Authors:  Inmaculada Lara-Cantón; Shiraz Badurdeen; Janneke Dekker; Peter Davis; Calum Roberts; Arjan Te Pas; Máximo Vento
Journal:  Pediatr Res       Date:  2022-01-07       Impact factor: 3.756

9.  Cardiovascular fetal-to-neonatal transition: an in silico model.

Authors:  Anneloes G Munneke; Joost Lumens; Tammo Delhaas
Journal:  Pediatr Res       Date:  2021-03-17       Impact factor: 3.756

10.  Correlation of pulse oximetry and apgar scoring in the normal newborns.

Authors:  Sandhya Chauhan; Prashant K Singh; Pratik Gahalaut; Prem L Prasad
Journal:  J Clin Neonatol       Date:  2013-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.