Literature DB >> 17518403

Computer assisted orthopaedic surgical system for insertion of distal locking screws in intra-medullary nails: a valid and reliable navigation system.

S Malek1, R Phillips, A Mohsen, W Viant, M Bielby, K Sherman.   

Abstract

The insertion of distal locking screws is a difficult task in intra-medullary (IM) nailing operations of long bones and contributes a significant proportion to the overall operating time. The current technique to insert these screws uses numerous fluoroscopic images and depends on the skills and expertise of the surgeon. The Computer Assisted Orthopaedic Surgical System (CAOSS) was developed to assist orthopaedic surgeons in these operations. The laboratory based test results for insertion of distal locking screws in IM nailing procedures are presented and discussed in terms of accuracy and as part of the validation process to introduce new CAOS procedures into clinical use. This study shows that CAOSS in IM nailing is robust and reliable. Positional accuracy was shown to be within 0.3 mm and angular accuracy within 0.2 degrees with femoral IM nail. CAOSS was also shown to be very reliable and accurate at different angles of distal screws in fluoroscopic image space. Copyright 2005 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2005        PMID: 17518403     DOI: 10.1002/rcs.54

Source DB:  PubMed          Journal:  Int J Med Robot        ISSN: 1478-5951            Impact factor:   2.547


  7 in total

Review 1.  Meta-analysis suggests that the electromagnetic technique is better than the free-hand method for the distal locking during intramedullary nailing procedures.

Authors:  Yanbin Zhu; Hengrui Chang; Yiyang Yu; Wei Chen; Song Liu; Yingze Zhang
Journal:  Int Orthop       Date:  2016-06-02       Impact factor: 3.075

2.  Fluoroscopic freehand and electromagnetic-guided targeting system for distal locking screws of humeral intramedullary nail.

Authors:  P Persiani; M Gurzi; O Moreschini; G Di Giacomo; C Villani
Journal:  Musculoskelet Surg       Date:  2016-11-22

3.  Surgical technique: static intramedullary nailing of the femur and tibia without intraoperative fluoroscopy.

Authors:  Neil J White; Anthony T Sorkin; Geoffrey Konopka; Todd O McKinley
Journal:  Clin Orthop Relat Res       Date:  2011-03-03       Impact factor: 4.176

4.  Intelligent diagnosis of jaundice with dynamic uncertain causality graph model.

Authors:  Shao-Rui Hao; Shi-Chao Geng; Lin-Xiao Fan; Jia-Jia Chen; Qin Zhang; Lan-Juan Li
Journal:  J Zhejiang Univ Sci B       Date:  2017-05       Impact factor: 3.066

5.  Comparison of free-hand fluoroscopic guidance and electromagnetic navigation in distal locking of tibia intramedullary nails.

Authors:  Yinsheng Wang; Bing Han; Zhigang Shi; Yu Fu; Yong Ye; Juehua Jing; Jun Li
Journal:  Medicine (Baltimore)       Date:  2018-07       Impact factor: 1.889

6.  Endoscopy-assisted distal locking of an intramedullary nail: A new experimental technique to reduce radiation exposure during distal locking of the intramedullary nails.

Authors:  Serkan Davut; Yunus Doğramacı
Journal:  Jt Dis Relat Surg       Date:  2021-11-19

7.  Validity of a Novel Digitally Enhanced Skills Training Station for Freehand Distal Interlocking.

Authors:  Torsten Pastor; Tatjana Pastor; Philipp Kastner; Firas Souleiman; Matthias Knobe; Boyko Gueorguiev; Markus Windolf; Jan Buschbaum
Journal:  Medicina (Kaunas)       Date:  2022-06-07       Impact factor: 2.948

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.