Quality control procedures for dose-response curve generation using nanoliter dispense technologies.

Catherine Quintero1, Craig Rosenstein, Bethany Hughes, Richard Middleton, Ilona Kariv.   

Abstract

With the advancement of high-throughput biomolecular screening techniques to the lead optimization stage, there is a critical need to quality control (QC) dose-response curves generated by robotic liquid handlers to ensure accurate affinity determinations. One challenge in evaluating the performance of liquid handlers is identifying and validating a robust method for testing dispense volumes across different instruments. Although traditional automated liquid handlers are still considered the standard platform in many laboratories, nanoliter dispensers are becoming more common and pose new challenges for routine quality control procedures. For example, standard gravimetric measurements are unreliable for testing the accuracy of nanoliter liquid dispenses. However, nanoliter dispensing technology allows for the conservation of compound, reduces compound carryover from well to well through discrete dispenses, and eliminates the need for intermediate compound dilution steps to achieve a low final DMSO assay concentration. Moreover, an intermediate dilution step in aqueous solution might result in compound precipitation at high concentrations. This study compared representative automation procedures done on a variety of liquid dispensers, including manual, traditional, and nanodispense volumes. The data confirmed the importance of establishing robust QC procedures for dose-response generation in addition to accuracy and precision determinations for each instrument, and they validated the use of nanoliter pipettors for dose-response testing. The results of this study also support the requirement for thorough mixing during serial compound dilutions prepared for high-throughput lead optimization strategies using traditional liquid handlers.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17517899     DOI: 10.1177/1087057107302114

Source DB:  PubMed          Journal:  J Biomol Screen        ISSN: 1087-0571


  2 in total

1.  Log-scale dose response of inhibitors on a chip.

Authors:  Jae Young Yun; Sachin Jambovane; Se-Kwon Kim; Sung-Hak Cho; Evert C Duin; Jong Wook Hong
Journal:  Anal Chem       Date:  2011-07-19       Impact factor: 6.986

2.  Inkjet metrology: high-accuracy mass measurements of microdroplets produced by a drop-on-demand dispenser.

Authors:  R Michael Verkouteren; Jennifer R Verkouteren
Journal:  Anal Chem       Date:  2009-10-15       Impact factor: 6.986

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.