Literature DB >> 17517416

Opening angle and residual strain in a three-layered model of pig oesophagus.

Jingbo Zhao1, Xudong Chen, Jian Yang, Donghua Liao, Hans Gregersen.   

Abstract

Studies of various biological tissues have shown that residual strains are important for tissue function. Since a force balance exists in whole wall thickness specimens cut radially, it is evident that layer separation is an important procedure in the understanding of the meaning of residual stresses and strains. The present study investigated the zero-stress state and residual strain distribution in a three-layer model of the pig oesophagus. The middle part of the oesophagus was obtained from six slaughterhouse pigs. Four 3-mm-wide rings were serially cut from each oesophagus. Two of them were used for separating the wall into mucosa-submucosa, inner and outer muscle layers. The remaining two rings were kept as intact rings. The inner and outer circumferences and wall thickness of different layers in intact and separated rings were measured from the digital images in the no-load state and zero-stress state. The opening angle was measured and the residual strain at the inner and outer surface of different layers and the intact wall were computed. Compared with intact sectors (62.8+/-9.8 degrees ), the opening angles were smaller in the inner muscle sectors (37.2+/-11.4 degrees , P<0.01), whereas the opening angles of mucosa-submucosa (63.9+/-6.8 degrees ) and outer muscle sectors (63.9+/-6.8 degrees ) did not differ (P>0.1). Referenced to the zero-stress state of the intact sectors, the inner and outer residual strains of the intact rings was -0.128+/-0.043 and outer residual strain was 0.308+/-0.032. Referenced to the "true" zero-stress state of separated three-layered sectors, the inner residual strain of intact rings were -0.223+/-0.021 (P<0.01) and 0.071+/-0.022 (P<0.01). Referenced to the "true" zero-stress state, the residual strain distribution of different layers in intact rings was shown that the inner surface residual strain was negative at mucosa-submucosa and inner muscle layers and was positive at outer muscle layer, whereas the outer surface residual strain was negative at the mucosa-submucosa layer and positive at the inner and outer muscle layers. For the separated different layered rings, the inner residual strain was negative and outer residual strain was positive; however, the absolute values did not differ (P>0.1). In conclusion, it is possible to microsurgically separate the oesophagus into three layers, i.e., mucosa-submucosa, inner muscle and outer muscle layers, the residual strain differ between the layers, and the residual strain distribution was more uniform after the layers were separated.

Entities:  

Mesh:

Year:  2007        PMID: 17517416     DOI: 10.1016/j.jbiomech.2007.04.002

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  4 in total

1.  Folding artificial mucosa with cell-laden hydrogels guided by mechanics models.

Authors:  Hon Fai Chan; Ruike Zhao; German A Parada; Hu Meng; Kam W Leong; Linda G Griffith; Xuanhe Zhao
Journal:  Proc Natl Acad Sci U S A       Date:  2018-07-02       Impact factor: 11.205

2.  Biomechanical analysis of sheep oesophagus subjected to biaxial testing including hyperelastic constitutive model fitting.

Authors:  Harry Ngwangwa; Thanyani Pandelani; Makhosasana Msibi; Israel Mabuda; Letlhogonolo Semakane; Fulufhelo Nemavhola
Journal:  Heliyon       Date:  2022-05-05

3.  Modeling of the mechanical function of the human gastroesophageal junction using an anatomically realistic three-dimensional model.

Authors:  R Yassi; L K Cheng; V Rajagopal; M P Nash; J A Windsor; A J Pullan
Journal:  J Biomech       Date:  2009-05-28       Impact factor: 2.712

4.  Toward Elucidating the Physiological Impacts of Residual Stresses in the Colorectum.

Authors:  Y Zhao; S Siri; B Feng; D M Pierce
Journal:  J Biomech Eng       Date:  2022-01-01       Impact factor: 2.097

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.