Histological evaluation of oral implants inserted with different surgical techniques into the trabecular bone of goats.

Manal M Shalabi1, Johannes G C Wolke, Anja J E de Ruijter, John A Jansen.   

Abstract

OBJECTIVE: The aim of this study was to investigate the influence of implant surface topography and surgical technique on bone response.
MATERIAL AND METHODS: For the experiment, 48 screw-designed implants were used with two different surface finishes, i.e. machined and 'blasted, etched'. The implants were inserted into the left and right medial femoral condyle of eight goats using three different surgical approaches: press-fit (implant diameter=implant bed diamete(r), undersized (implant bed diameter<implant diameter) and osteotome. Each femoral condyle received three implants. After an implantation period of 12 weeks, the implants were retrieved and prepared for histological and histomorphometrical evaluation (bone contact and bone mass).
RESULTS: Light microscopy revealed that in general, the bone response to all implants was very similar. On the other hand, histomorphometry suggested that the bone-to-implant contact for the 'blasted, etched' implants inserted by an undersized technique was higher compared with machined implants and the other surgical approaches, but the observed differences were not significant. Bone mass measurements did not reveal the occurrence of clear differences between groups and surgical approaches.
CONCLUSION: Supported by our findings, we conclude that implants provided with a 'blasted, etched' surface and installed in trabecular bone using an undersized preparation technique appear to support an enhanced bone-implant contact. The use of an osteotome technique did not lead to improved results.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17517059     DOI: 10.1111/j.1600-0501.2007.01362.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  6 in total

1.  Biomechanics of the press-fit phenomenon in dental implantology: an image-based finite element analysis.

Authors:  Gianni Frisardi; Sandro Barone; Armando V Razionale; Alessandro Paoli; Flavio Frisardi; Antonio Tullio; Aurea Lumbau; Giacomo Chessa
Journal:  Head Face Med       Date:  2012-05-29       Impact factor: 2.151

2.  Biomechanical evaluation of oversized drilling technique on primary implant stability measured by insertion torque and resonance frequency analysis.

Authors:  Gorka Santamaría-Arrieta; Aritza Brizuela-Velasco; Felipe J Fernández-González; David Chávarri-Prado; Yelko Chento-Valiente; Eneko Solaberrieta; Markel Diéguez-Pereira; José-Antonio Vega; Jaime Yurrebaso-Asúa
Journal:  J Clin Exp Dent       Date:  2016-07-01

3.  Comparison of bone-to-implant contact and bone volume around implants placed with or without site preparation: a histomorphometric study in rabbits.

Authors:  Merav Folkman; Alina Becker; Isabelle Meinster; Mahmoud Masri; Zeev Ormianer
Journal:  Sci Rep       Date:  2020-07-24       Impact factor: 4.379

4.  New Osseodensification Implant Site Preparation Method to Increase Bone Density in Low-Density Bone: In Vivo Evaluation in Sheep.

Authors:  Paolo Trisi; Marco Berardini; Antonello Falco; Michele Podaliri Vulpiani
Journal:  Implant Dent       Date:  2016-02       Impact factor: 2.454

5.  Assessment of Temperature Rise and Time of Alveolar Ridge Splitting by Means of Er:YAG Laser, Piezosurgery, and Surgical Saw: An Ex Vivo Study.

Authors:  Jacek Matys; Rafał Flieger; Marzena Dominiak
Journal:  Biomed Res Int       Date:  2016-11-10       Impact factor: 3.411

6.  The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs.

Authors:  Danilo Alessio Di Stefano; Vittoria Perrotti; Gian Battista Greco; Claudia Cappucci; Paolo Arosio; Adriano Piattelli; Giovanna Iezzi
Journal:  J Adv Prosthodont       Date:  2018-06-12       Impact factor: 1.904

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.