Influence of instrument size on endoscopic task performance in pediatric intracorporeal knot tying: smaller instruments are better in infants.

Alex C H Lee1, Munther J Haddad, George B Hanna.   

Abstract

BACKGROUND: The widespread availability of adult minimal access surgical (MAS) equipment together with resource constraints have led pediatric surgeons to adopt the adult setup. This study examined the influence of instrument size on task outcome and physical impact on the surgeon in pediatric endoscopic intracorporeal knot tying.
METHODS: Sixteen surgeons participated in this study in which they had to tie surgeon's knots inside a neonatal simulator box with an endoscopic field of 40 mm. All surgeons tied 20 knots using paired pediatric needle-holders and 20 knots using paired adult needle-holders in a randomized order. Knot quality score (KQS) and wrap length were used as indices of knot quality and wrap tightness. Electromyographic (EMG) recordings of the upper limb muscle groups were used to indicate muscular recruitment. A questionnaire on discomfort and instrument preference was also completed by the surgeons.
RESULTS: A total of 640 knots were analyzed. Median time was shorter for pediatric needle-holders than for adult needle-holders (94 s vs. 103 s; p < 0.001); however, KQS (0.271 vs. 0.260; p = 0.509) and the tightness around the tube (86 mm vs. 86 mm; p = 0.255) were not significantly different. The proportion of knots that completely slipped was also similar for both needle-holders (19% vs. 22%; p = 0.322). The normalized EMG values when using adult needle-holders were significantly higher than when using pediatric needle-holders in all upper limb muscle groups with the exception of left forearm extensors (p = 0.460). The surgeons reported less discomfort with the pediatric needle-holders in the right forearm and hand, and 13 surgeons expressed overall preference for the smaller instruments.
CONCLUSION: Endoscopic knot tying was performed faster in the neonatal simulator box using pediatric needle-holders while maintaining knot quality. Upper limb muscular recruitment was reduced resulting in less discomfort for the surgeon.

Entities:  

Mesh:

Year:  2007        PMID: 17516118     DOI: 10.1007/s00464-007-9311-z

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  18 in total

1.  Normalisation of EMG amplitude: an evaluation and comparison of old and new methods.

Authors:  A Burden; R Bartlett
Journal:  Med Eng Phys       Date:  1999-05       Impact factor: 2.242

2.  Effect of intracorporeal-extracorporeal instrument length ratio on endoscopic task performance and surgeon movements.

Authors:  T A Emam; G B Hanna; C Kimber; P Dunkley; A Cuschieri
Journal:  Arch Surg       Date:  2000-01

3.  Ergonomic problems associated with laparoscopic surgery.

Authors:  R Berguer; D L Forkey; W D Smith
Journal:  Surg Endosc       Date:  1999-05       Impact factor: 4.584

4.  An ergonomic study of the optimum operating table height for laparoscopic surgery.

Authors:  R Berquer; W D Smith; S Davis
Journal:  Surg Endosc       Date:  2001-11-16       Impact factor: 4.584

5.  Laparoscopic treatment of biliary atresia and choledochal cyst.

Authors:  Marcelo Martinez-Ferro; Edward Esteves; Pablo Laje
Journal:  Semin Pediatr Surg       Date:  2005-11       Impact factor: 2.754

Review 6.  Physiology and interpretation of the electromyogram.

Authors:  G Kamen; G E Caldwell
Journal:  J Clin Neurophysiol       Date:  1996-09       Impact factor: 2.177

7.  Thoracoscopic repair of esophageal atresia and tracheoesophageal fistula: a multi-institutional analysis.

Authors:  George W Holcomb; Steven S Rothenberg; Klaas M A Bax; Marcelo Martinez-Ferro; Craig T Albanese; Daniel J Ostlie; David C van Der Zee; C K Yeung
Journal:  Ann Surg       Date:  2005-09       Impact factor: 12.969

8.  Whither minimal access surgery: tribulations and expectations.

Authors:  A Cuschieri
Journal:  Am J Surg       Date:  1995-01       Impact factor: 2.565

9.  Electromyographic amplitude normalization methods: improving their sensitivity as diagnostic tools in gait analysis.

Authors:  J F Yang; D A Winter
Journal:  Arch Phys Med Rehabil       Date:  1984-09       Impact factor: 3.966

10.  Influence of direction of view, target-to-endoscope distance and manipulation angle on endoscopic knot tying.

Authors:  G B Hanna; S Shimi; A Cuschieri
Journal:  Br J Surg       Date:  1997-10       Impact factor: 6.939

View more
  6 in total

1.  A multi-degree-of-freedom needle driver with a short tip and small shaft for pediatric laparoscopic surgery: in vivo assessment of multi-directional suturing on the vertical plane of the liver in rabbits.

Authors:  Shinya Takazawa; Tetsuya Ishimaru; Masahiro Fujii; Kanako Harada; Kyoichi Deie; Jun Fujishiro; Naohiko Sugita; Mamoru Mitsuishi; Tadashi Iwanaka
Journal:  Surg Endosc       Date:  2015-10-28       Impact factor: 4.584

2.  Assessment of suturing in the vertical plane shows the efficacy of the multi-degree-of-freedom needle driver for neonatal laparoscopy.

Authors:  Shinya Takazawa; Tetsuya Ishimaru; Masahiro Fujii; Kanako Harada; Naohiko Sugita; Mamoru Mitsuishi; Tadashi Iwanaka
Journal:  Pediatr Surg Int       Date:  2013-11       Impact factor: 1.827

3.  Objective evidence for optimum knot configuration.

Authors:  Alex C H Lee; Ramy R R Fahmy; George B Hanna
Journal:  World J Surg       Date:  2008-12       Impact factor: 3.352

4.  Optimizing working space in laparoscopy: CT-measurement of the effect of neuromuscular blockade and its reversal in a porcine model.

Authors:  John Vlot; Patricia A Specht; René M H Wijnen; Joost van Rosmalen; Egbert G Mik; Klaas M A Bax
Journal:  Surg Endosc       Date:  2014-11-01       Impact factor: 4.584

5.  Virtually transparent surgical instruments in endoscopic surgery with augmentation of obscured regions.

Authors:  Yuta Koreeda; Yo Kobayashi; Satoshi Ieiri; Yuya Nishio; Kazuya Kawamura; Satoshi Obata; Ryota Souzaki; Makoto Hashizume; Masakatsu G Fujie
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-04-02       Impact factor: 2.924

6.  Minimally invasive surgery in neonates and infants.

Authors:  Tiffany Lin; Ashwin Pimpalwar
Journal:  J Indian Assoc Pediatr Surg       Date:  2010-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.