Literature DB >> 17515719

Effect of right ventricular pacing on cardiac apex rotation assessed by a gyroscopic sensor.

Emanuela Marcelli1, Laura Cercenelli, Mario Parlapiano, Roberto Fumero, Paola Bagnoli, Maria Laura Costantino, Gianni Plicchi.   

Abstract

To quantify cardiac apex rotation (CAR), the authors recently proposed the use of a Coriolis force sensor (gyroscope) as an alternative to other complex techniques. The aim of this study was to evaluate the effects of right ventricular (RV) pacing on CAR. A sheep heart was initially paced from the right atrium to induce a normal activation sequence at a fixed heart rate (AAI mode) and then an atrioventricular pacing was performed (DOO mode, AV delay = 60 ms). A small gyroscope was epicardially glued on the cardiac apex to measure the angular velocity (Ang V). From AAI to DOO pacing mode, an increase (+9.2%, p < 0.05) of the maximum systolic twisting velocity (Ang VMAX) and a marked decrease (-19.9%, p < 0.05) of the maximum diastolic untwisting velocity (Ang VMIN) resulted. RV pacing had negligible effects (-3.1%, p = 0.09) on the maximum angle of CAR, obtained by integrating Ang V. The hemodynamic parameters of systolic (LVdP/dtMAX) and diastolic (LVdP/dtMIN) cardiac function showed slight variations (-3.8%, p < 0.05 and +3.9%, p < 0.05, respectively). Results suggest that cardiac dyssynchrony induced by RV pacing can alter the normal physiological ventricular twist patterns, particularly affecting diastolic untwisting velocity.

Entities:  

Mesh:

Year:  2007        PMID: 17515719     DOI: 10.1097/MAT.0b013e31805370e3

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  3 in total

1.  Robust model-based quantification of global ventricular torsion from spatially sparse three-dimensional time series data by orthogonal distance regression: evaluation in a canine animal model under different pacing regimes.

Authors:  Sven Zenker; Hyung Kook Kim; Gilles Clermont; Michael R Pinsky
Journal:  Pacing Clin Electrophysiol       Date:  2012-08-16       Impact factor: 1.976

2.  Gyrocardiography: A New Non-invasive Monitoring Method for the Assessment of Cardiac Mechanics and the Estimation of Hemodynamic Variables.

Authors:  Mojtaba Jafari Tadi; Eero Lehtonen; Antti Saraste; Jarno Tuominen; Juho Koskinen; Mika Teräs; Juhani Airaksinen; Mikko Pänkäälä; Tero Koivisto
Journal:  Sci Rep       Date:  2017-07-28       Impact factor: 4.379

3.  An Implantable Sensorized Lead for Continuous Monitoring of Cardiac Apex Rotation.

Authors:  Emanuela Marcelli; Laura Cercenelli
Journal:  Sensors (Basel)       Date:  2018-11-30       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.