Literature DB >> 17513035

Automated tracking of the mitral valve annulus motion in apical echocardiographic images using multidimensional dynamic programming.

Shelly T Nevo1, Marijn van Stralen, Albert M Vossepoel, Johan H C Reiber, Nico de Jong, Antonius F W van der Steen, Johan G Bosch.   

Abstract

We developed a semiautomatic method for tracking the mitral valve annulus (MVA) in echocardiographic images, in particular, tracking the septal and the lateral mitral valve hinge points. The algorithm is based on multidimensional dynamic programming combined with apodized block matching. The method was tested on single-beat apical four chamber image sequences of 20 patients with acute myocardial infarction. The automated tracking results were evaluated by comparing them with the average manual tracking results of two experts. The mitral valve hinge point displacements and the total mitral excursions obtained by the automatic technique agreed well with those obtained manually and outperformed two commonly used tracking methods (forward tracking and minimum tracking). In conclusion, this novel semiautomatic tracking method is clinically valuable and capable of tracking the MVA motion within the limits of interobserver variability. The technique is robust, even in low frame rate, redigitized VCR images of clinical quality.

Entities:  

Mesh:

Year:  2007        PMID: 17513035     DOI: 10.1016/j.ultrasmedbio.2007.03.007

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  6 in total

1.  Left ventricle wall motion quantification from echocardiographic images by non-rigid image registration.

Authors:  Ahmad Shalbaf; Hamid Behnam; Zahra Alizade-Sani; Maryam Shojaifard
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-07-31       Impact factor: 2.924

2.  Mitral annulus segmentation from four-dimensional ultrasound using a valve state predictor and constrained optical flow.

Authors:  Robert J Schneider; Douglas P Perrin; Nikolay V Vasilyev; Gerald R Marx; Pedro J del Nido; Robert D Howe
Journal:  Med Image Anal       Date:  2011-12-04       Impact factor: 8.545

3.  Mitral valve prolapse: a source of arrhythmias?

Authors:  E E van der Wall; M J Schalij
Journal:  Int J Cardiovasc Imaging       Date:  2010-02       Impact factor: 2.357

4.  A new automated system to identify a consistent sampling position to make tissue Doppler and transmitral Doppler measurements of E, E' and E/E'.

Authors:  Niti M Dhutia; Graham D Cole; Keith Willson; Daniel Rueckert; Kim H Parker; Alun D Hughes; Darrel P Francis
Journal:  Int J Cardiol       Date:  2010-11-20       Impact factor: 4.164

5.  Identification of Mitral Annulus Hinge Point Based on Local Context Feature and Additive SVM Classifier.

Authors:  Jianming Zhang; Yangchun Liu; Wei Xu
Journal:  Comput Math Methods Med       Date:  2015-05-18       Impact factor: 2.238

6.  Time-resolved tracking of the atrioventricular plane displacement in Cardiovascular Magnetic Resonance (CMR) images.

Authors:  Felicia Seemann; Ulrika Pahlm; Katarina Steding-Ehrenborg; Ellen Ostenfeld; David Erlinge; Jean-Luc Dubois-Rande; Svend Eggert Jensen; Dan Atar; Håkan Arheden; Marcus Carlsson; Einar Heiberg
Journal:  BMC Med Imaging       Date:  2017-02-28       Impact factor: 1.930

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.