Literature DB >> 17512936

Determination of chlorophenols in water samples using simultaneous dispersive liquid-liquid microextraction and derivatization followed by gas chromatography-electron-capture detection.

Nazir Fattahi1, Yaghoub Assadi, Mohammad Reza Milani Hosseini, Elham Zeini Jahromi.   

Abstract

Simultaneous dispersive liquid-liquid microextraction (DLLME) and derivatization combined with gas chromatography-electron-capture detection (GC-ECD) was used to determine chlorophenols (CPs) in water sample. In this derivatization/extraction method, 500 microL acetone (disperser solvent) containing 10.0 microL chlorobenzene (extraction solvent) and 50 microL acetic anhydride (derivatization reagent) was rapidly injected by syringe in 5.00 mL aqueous sample containing CPs (analytes) and K(2)CO(3) (0.5%, w/v). Within a few seconds the analytes derivatized and extracted at the same time. After centrifugation, 0.50 microL of sedimented phase containing enriched analytes was determined by GC-ECD. Some effective parameters on derivatization and extraction, such as extraction and disperser solvent type and their volume, amount of derivatization reagent, derivatization and extraction time, salt addition and amount of K(2)CO(3) were studied and optimized. Under the optimum conditions, enrichment factors and recoveries are in the range of 287-906 and 28.7-90.6%, respectively. The calibration graphs are linear in the range of 0.02-400 microg L(-1) and limit of detections (LODs) are in the range of 0.010-2.0 microg L(-1). The relative standard deviations (RSDs, for 200 microg L(-1) of MCPs, 100 microg L(-1) of DCPs, 4.00 microg L(-1) of TCPs, 2.00 microg L(-1) of TeCPs and PCP in water) with and without using internal standard are in the range of 0.6-4.7% (n=7) and 1.7-7.1% (n=7), respectively. The relative recoveries of well, tap and river water samples which have been spiked with different levels of CPs are 91.6-104.7, 80.8-117.9 and 83.3-101.3%, respectively. The obtained results show that simultaneous DLLME and derivatization combined with GC-ECD is a fast simple method for the determination of CPs in water samples.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17512936     DOI: 10.1016/j.chroma.2007.04.062

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  9 in total

Review 1.  Methods for quantification of growth and productivity in anaerobic microbiology and biotechnology.

Authors:  Lisa-Maria Mauerhofer; Patricia Pappenreiter; Christian Paulik; Arne H Seifert; Sébastien Bernacchi; Simon K-M R Rittmann
Journal:  Folia Microbiol (Praha)       Date:  2018-11-16       Impact factor: 2.099

2.  Optimization and determination of Cd (II) in different environmental water samples with dispersive liquid-liquid microextraction preconcentration combined with inductively coupled plasma optical emission spectrometry.

Authors:  Maryam Salahinejad; Fereydoon Aflaki
Journal:  Environ Monit Assess       Date:  2010-07-23       Impact factor: 2.513

3.  Application of dispersive liquid-liquid microextraction and reversed phase-high performance liquid chromatography for the determination of two fungicides in environmental water samples.

Authors:  Jing Cheng; Yiwen Zhou; Mei Zuo; Liping Dai; Xiaojie Guo
Journal:  Int J Environ Anal Chem       Date:  2010-08-11       Impact factor: 2.826

4.  Spin-column micro-solid phase extraction of chlorophenols using MFU-4l metal-organic framework.

Authors:  Ali Esrafili; Mahnaz Ghambarian; Mohammad Tajik; Mahroo Baharfar
Journal:  Mikrochim Acta       Date:  2019-12-10       Impact factor: 5.833

5.  Determination of some B Vitamins in Sour Cherry Juice Using Dispersive Liquid-liquid Microextraction Followed by High-performance Liquid Chromatography.

Authors:  Parvin Parsaei; Manouchehr Bahmaei; AliReza Ghannadi
Journal:  Iran J Pharm Res       Date:  2014       Impact factor: 1.696

6.  Cost-Effective Detection of Perfluoroalkyl Carboxylic Acids with Gas Chromatography: Optimization of Derivatization Approaches and Method Validation.

Authors:  Zhen Li; Hongwei Sun
Journal:  Int J Environ Res Public Health       Date:  2019-12-21       Impact factor: 3.390

7.  [Determination of 19 chlorophenols in fish by QuEChERS-gas chromatography-mass spectrometry].

Authors:  Yinghua Mu; Jiali Xing; Jian Shen; Lu Ying; Lingyan Mao; Xiaorong Xu; Yongjiang Lou; Xi Wu
Journal:  Se Pu       Date:  2022-05-08

8.  Detection of Polycyclic Aromatic Hydrocarbons in Water Samples by Annular Platform-Supported Ionic Liquid-Based Headspace Liquid-Phase Microextraction.

Authors:  Xiaojie Sun; Jie Tan; Haiyan Ding; Xiaojie Tan; Jun Xing; Lihong Xing; Yuxiu Zhai; Zhaoxin Li
Journal:  J Anal Methods Chem       Date:  2018-09-27       Impact factor: 2.193

9.  An all-solid-state NO3- ion-selective electrode with gold nanoparticles solid contact layer and molecularly imprinted polymer membrane.

Authors:  Lei Zhang; Zhengying Wei; Pengcheng Liu
Journal:  PLoS One       Date:  2020-10-15       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.