Literature DB >> 1751180

Mean velocities and Reynolds stresses within regurgitant jets produced by tilting disc valves.

J T Baldwin1, J M Tarbell, S Deutsch, D B Geselowitz.   

Abstract

Fluid velocities were measured with a two-component laser Doppler anemometry system in the regurgitant jet regions of Bjork-Shiley Delrin monostrut tilting disc valves mounted within a Plexiglas model of the 70 cm3 Penn State electric left ventricular assist device. At each measurement location, 250 instantaneous velocity realizations were collected at times when regurgitation through the valves occurred. The maximum Reynolds shear and normal stresses were calculated after filtering the data. Results show that Reynolds shear and normal stresses proximal to the mitral valve were elevated to magnitudes of 9,000 dynes/cm2 and 20,000 dynes/cm2, respectively. The peak Reynolds stresses near the mitral valve occurred during early systole, when regurgitant jet velocities reached magnitudes as high as 440 cm/sec. The Reynolds shear and normal stresses proximal to the aortic valve reached magnitudes of 9,900 dynes/cm2 and 20,500 dynes/cm2, respectively. The peak Reynolds stresses near the aortic valve occurred during early diastole, when regurgitant jet velocities were as high as 280 cm/sec. These high Reynolds stresses created by turbulent regurgitant flow have the potential to cause significant blood damage.

Entities:  

Mesh:

Year:  1991        PMID: 1751180

Source DB:  PubMed          Journal:  ASAIO Trans        ISSN: 0889-7190


  4 in total

1.  Transient fluid-structure coupling for simulation of a trileaflet heart valve using weak coupling.

Authors:  Yos S Morsi; William W Yang; Cynthia S Wong; Subrat Das
Journal:  J Artif Organs       Date:  2007-06-20       Impact factor: 1.731

2.  Dynamics of a mechanical monoleaflet heart valve prosthesis in the closing phase: effect of squeeze film.

Authors:  C Gill-Jeong; K B Chandran
Journal:  Ann Biomed Eng       Date:  1995 Mar-Apr       Impact factor: 3.934

3.  Instantaneous back flow through peripheral clearance of Medtronic Hall tilting disc valve at the moment of closure.

Authors:  C S Lee; K B Chandran
Journal:  Ann Biomed Eng       Date:  1994 Jul-Aug       Impact factor: 3.934

4.  Special Issue on Professor John M. Tarbell's Contribution to Cardiovascular Engineering.

Authors:  Hanjoong Jo; Keefe Manning; John M Tarbell
Journal:  Cardiovasc Eng Technol       Date:  2021-01-07       Impact factor: 2.495

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.