Literature DB >> 17511015

Hollow-fiber liquid-phase microextraction prior to low-temperature electrothermal vaporization ICP-MS for trace element analysis in environmental and biological samples.

Linbo Xia1, Yunli Wu, Bin Hu.   

Abstract

A new method of hollow-fiber liquid-phase microextraction (HF-LPME) prior to electrothermal vaporization (ETV) inductively coupled plasma mass spectrometry (ICP-MS) determination of trace Cu, Zn, Pd, Cd, Hg, Pb and Bi, based on gaseous compounds introduction into the plasma as their diethyldithiocarbmate (DDTC) chelates, was developed. The use of the reagent DDTC as chemical modifier could not only enhance the analytical signals, but also decrease the vaporization temperature. At a temperature of 1300 degrees C, trace Cu, Zn, Pd, Cd, Hg, Pb and Bi can be vaporized completely into the ICP. The factors affecting the formation of the chelates and their vaporization behaviors were investigated in detail, and the microextraction conditions were optimized. Under the optimized conditions, the detection limits of the proposed method were 12.4, 28.7, 7.9, 4.5, 3.3, 4.8 and 1.6 pg ml(-1) for Cu, Zn, Pd, Cd, Hg, Pb and Bi, respectively. Enrichment factors of 305, 284, 24, 29, 20, 73 and 43 could be achieved within 15 min of extraction time, and the relative standard deviations (RSDs) for the seven determinations of 0.5 ng ml(-1) of target analytes were 8.8, 6.9, 7.1, 9.4, 10.2, 6.1 and 10.8%, respectively. The newly developed method has been applied to the determination of trace Cu, Zn, Pd, Cd, Hg, Pb and Bi in environmental water and human serum samples, and the recoveries for the spiked samples were in the range of 88-116%. In order to validate this method, two certified reference materials, GBW08501 peach leaves and GBW(E)080040 seawater, were analyzed, and the determined values were in good agreement with the certified values.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17511015     DOI: 10.1002/jms.1216

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  2 in total

1.  An accurate and sensitive analytical strategy for the determination of palladium in aqueous samples: slotted quartz tube flame atomic absorption spectrometry with switchable liquid-liquid microextraction after preconcentration using a Schiff base ligand.

Authors:  Merve Fırat; Emine Gülhan Bakırdere
Journal:  Environ Monit Assess       Date:  2019-02-05       Impact factor: 2.513

2.  Pseudo-stir bar hollow fiber solid/liquid phase microextraction combined with anodic stripping voltammetry for determination of lead and cadmium in water samples.

Authors:  Zarrin Es'haghi; Hasan Ali Hoseini; Saeed Mohammadi-Nokhandani; Javad Ebrahimi
Journal:  J Adv Res       Date:  2013-11-20       Impact factor: 10.479

  2 in total