Literature DB >> 17509412

A scanning electron microscopy evaluation of microfractures, deformation and separation in EndoSequence and Profile nickel-titanium rotary files using an extracted molar tooth model.

Keven S Herold1, Bradford R Johnson, Christopher S Wenckus.   

Abstract

The development of microfractures in the EndoSequence nickel-titanium rotary (NTR) file (Brassler USA, Savannah, GA) and Profile NTR file was evaluated by using scanning electron microscopy (SEM). Seventy-three maxillary buccal roots and 53 mandibular mesial roots with an average canal curvature of 37 degrees were randomly assigned to one of three groups and prepared with 21-mm .06 taper NTR files as follows: (1) EndoSequence at 300 rpm, (2) EndoSequence at 600 rpm, and (3) ProFile at 300 rpm. File sizes .45 to .20 were used in a crown-down technique to a master apical file (MAF) size of .35/.06. The MAF instruments were evaluated by SEM before use, after completion of 7 canals, and after completion of 14 canals. All EndoSequence instruments developed microfractures by the seven-canal evaluation. The ProFile instruments showed no microfractures at the 7- or 14-canal evaluations. EndoSequence files separated at a higher rate than ProFile instruments. Under the conditions of this study, unique file design and electropolishing did not inhibit the development of microfractures in EndoSequence NTR.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17509412     DOI: 10.1016/j.joen.2007.03.014

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  7 in total

1.  Effect of NaOCl and EDTA Solutions on Topography of ESX, TruShape and ProTaper Gold NiTi Rotary Instruments - An Atomic Force Microscopic Study.

Authors:  Abhijit M Pallewar; Roopadevi Garlapati; Bolla Nagesh; Praveen Kumar Gali; Chukka Ram Sunil; Varri Sujana
Journal:  J Conserv Dent       Date:  2020-08-04

Review 2.  A Review of the Various Surface Treatments of NiTi Instruments.

Authors:  Zahed Mohammadi; Mohammad Karim Soltani; Sousan Shalavi; Saeed Asgary
Journal:  Iran Endod J       Date:  2014-10-07

3.  Multimethod Assessment of the Cyclic Fatigue Strength of ProGlider, Edge Glide Path and R-Pilot Endodontic Instruments.

Authors:  Jorge N R Martins; Duarte Marques; Isabel Vasconcelos; Sofia Arantes-Oliveira; João Caramês; Francisco Manuel Braz Fernandes
Journal:  Dent J (Basel)       Date:  2022-02-17

4.  Advancing Nitinol: From heat treatment to surface functionalization for nickel-titanium (NiTi) instruments in endodontics.

Authors:  Wai-Sze Chan; Karan Gulati; Ove A Peters
Journal:  Bioact Mater       Date:  2022-09-27

5.  An ex-vivo study on the shaping parameters of two nickel-titanium rotary systems compared with hand instruments.

Authors:  Maryam Ehsani; Samir Zahedpasha; Ali Akbar Moghadamnia; Jaber Mirjani
Journal:  Iran Endod J       Date:  2011-05-15

6.  Comparative Evaluation of Physical Surface Changes and Incidence of Separation in Rotary Nickel-Titanium Instruments: An in Vitro SEM Study.

Authors:  Rudra Kaul; Riyaz Farooq; Vibhuti Kaul; Shafayat Ullah Khateeb; Aamir Rashid Purra; Roopali Mahajan
Journal:  Iran Endod J       Date:  2014-07-05

7.  Comparison of Cyclic Fatigue Resistance of Five Nickel Titanium Rotary File Systems with Different Manufacturing Techniques.

Authors:  Mohsen Aminsobhani; Naghmeh Meraji; Ehsan Sadri
Journal:  J Dent (Tehran)       Date:  2015-09
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.