Literature DB >> 17509362

Biomechanical and biochemical assessment of properties of the anterior urethra after hypospadias repair in a rabbit model.

Marianna Lalla1, Carl Christian Danielsen, Helene Austevoll, Lars Henning Olsen, Troels Munch Jørgensen.   

Abstract

PURPOSE: We created a rabbit model to test hypospadias operations and investigate the biomechanical properties of the urethra at long-term followup using biomechanical and biochemical assessments.
MATERIALS AND METHODS: A total of 38 New Zealand White rabbits were randomized into 4 groups, including controls, sham operation and 2 operation groups (experimental creation of a hypospadias-like defect and acute repair, respectively). In operation group 1 the ventral urethral wall and dorsal plate were longitudinally incised, half of the ventral urethral wall was excised (hypospadias-like defect) and the incised urethra was tubularized (tubularized incised posterior plate urethroplasty group). In operation group 2 the urethra was mobilized from the corpora cavernosa, excised in its distal end (hypospadias-like defect) and advanced to the glanular tip (mobilization and advancement group). At 23 weeks postoperatively biochemical and biomechanical assessments were performed.
RESULTS: Maximum urethral strength and stiffness, strain at maximum load and the collagen weight fraction were not significantly different among the groups. Urethral diameter was larger and the total amount of collagen was higher in the mobilization and advancement group only (p <0.05). The mechanical quality of urethral collagen was decreased in the 2 operation groups (p <0.05).
CONCLUSIONS: This animal model proved to be useful for testing hypospadias operations and urethral mechanical properties. At long-term followup after experimental hypospadias repair biochemical and biomechanical assessments showed no differences among the groups in mechanical strength, strain and stiffness, and no indication of fibrosis. Consequently testing new hypospadias repair techniques and evaluating their biomechanical long-term results could be performed using hypospadiac animal models before clinical use.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17509362     DOI: 10.1016/j.juro.2007.01.139

Source DB:  PubMed          Journal:  J Urol        ISSN: 0022-5347            Impact factor:   7.450


  1 in total

1.  Urethral compliance in hypospadias operated by tubularized incised urethral plate (TIP) with and without a dorsal inlay graft: an experimental controlled study.

Authors:  L E Jesus; A Schanaider; G Patterson; A Marchenko; K J Aitken; B Leslie; D J Bagli; J L Pippi-Salle
Journal:  World J Urol       Date:  2012-12-09       Impact factor: 4.226

  1 in total