Literature DB >> 17507889

Doppler ultrasound criteria of physiological flow in asymmetrical vertebral arteries.

Marek Mysior1, Ludomir Stefańczyk.   

Abstract

BACKGROUND: Numerous publications have documented the usefulness of carotid ultrasonography. However, few studies report on criteria of flow evaluation in vertebral arteries. One reason is the greater anatomical variety of vertebral arteries, particularly the often encountered diameter asymmetry between sides. The purpose of this study was to assess the dependence of hemodynamics in vertebral arteries on their side-to-side diameter asymmetry. MATERIAL/
METHODS: Prospective color Doppler ultrasonography examinations of the vertebral arteries were performed on 113 adult volunteers (69 females, 44 males, mean age: 29.1+/-6.9 SD), free of symptoms of vertebrobasilar insufficiency, atherosclerotic lesions, anatomic anomalies, or signs of significant stenosis in spectral Doppler. The subjects were divided into four groups according to the degree of asymmetry between sides.
RESULTS: There were no statistically significant differences in the hemodynamics of the arteries with side-to-side diameter asymmetry of less than 25% (or 0.5 mm). In the remaining three groups, flow parameters differed considerably between sides. End diastolic velocity revealed the greatest dependence on diameter asymmetry.
CONCLUSIONS: Assessment of the hemodynamics of vertebral arteries should take side-to-side asymmetry into consideration. Arteries differing in diameter by up to 25% or 0.5 mm can be considered symmetrical. The most vulnerable flow parameter to side-to-side diameter asymmetry is the end diastolic velocity.

Entities:  

Mesh:

Year:  2007        PMID: 17507889

Source DB:  PubMed          Journal:  Med Sci Monit        ISSN: 1234-1010


  3 in total

1.  Safety of embolic protection device-assisted and unprotected intravascular ultrasound in evaluating carotid artery atherosclerotic lesions.

Authors:  Piotr Musialek; Piotr Pieniazek; Wieslawa Tracz; Lukasz Tekieli; Tadeusz Przewlocki; Anna Kablak-Ziembicka; Rafal Motyl; Zbigniew Moczulski; Jakub Stepniewski; Mariusz Trystula; Wojciech Zajdel; Agnieszka Roslawiecka; Krzysztof Zmudka; Piotr Podolec
Journal:  Med Sci Monit       Date:  2012-02

2.  Effect of normobaric hyperoxia on gentamicin-induced nephrotoxicity in rats.

Authors:  Majid Tavafi; Hasan Ahmadvand; Ahmad Tamjidipour; Bahram Rasolian
Journal:  Iran J Basic Med Sci       Date:  2014       Impact factor: 2.699

3.  Thymoquinone and curcumin attenuate gentamicin-induced renal oxidative stress, inflammation and apoptosis in rats.

Authors:  Ayman M Mahmoud; Osama M Ahmed; Sanaa R Galaly
Journal:  EXCLI J       Date:  2014-02-13       Impact factor: 4.068

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.