Literature DB >> 17507809

Hyperpolarized 3He ventilation defects and apparent diffusion coefficients in chronic obstructive pulmonary disease: preliminary results at 3.0 Tesla.

Grace Parraga1, Alexei Ouriadov, Andrea Evans, Shayna McKay, Wilfred W Lam, Aaron Fenster, Roya Etemad-Rezai, David McCormack, Giles Santyr.   

Abstract

OBJECTIVE: Hyperpolarized 3He magnetic resonance imaging (3He MRI) at 3.0 Tesla of healthy volunteers and chronic obstructive pulmonary disease (COPD) patients was performed for quantitative evaluation of ventilation defects and apparent diffusion coefficients (ADC) and for comparison to published results acquired at 1.5 Tesla. The reproducibility of 3He ADC and ventilation defects was also assessed in subjects scanned 3 times, twice within 10 minutes, and again within 7 +/- 2 days of the first MRI visit.
MATERIALS AND METHODS: Hyperpolarized 3He MRI was performed in 6 subjects. Two interleaved images with and without additional diffusion sensitization were acquired with the first image serving as a ventilation image from which defect score and volume were measured and the combination of the 2 images used to compute ADC maps and ADC histograms.
RESULTS: He MRI at 3.0 Tesla showed increased mean ADC and ADC standard deviation for subjects with COPD compared with healthy volunteers (ADC healthy volunteer (0.24 +/- 0.12 cm2/s), mild-moderate COPD (0.34 +/- 0.14 cm2/s), and severe COPD (0.47 +/- 0.21 cm2/s), and these values were similar to previously reported results acquired at 1.5 Tesla. Reproducibility of mean ADC was high (coefficient of variation 2% in severe COPD, 3% in mild-moderate COPD, 4% in healthy volunteers) across all 3 scans. Higher same-day scan reproducibility was observed for ventilation defect volume compared with 1-week scan reproducibility in this small group of subjects.
CONCLUSIONS: ADC values for emphysematous lungs were significantly increased compared with healthy lungs in age-matched subjects, and all values were comparable to those reported previously at 1.5 Tesla. Ventilation defect score and ventilation defect volume results were also comparable to results previously reported in COPD subjects Reproducibility of ADC for same-day scan-rescan and 7-day rescan was high and similar to previously reported results.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17507809     DOI: 10.1097/01.rli.0000262571.81771.66

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  29 in total

Review 1.  Quantitative pulmonary imaging using computed tomography and magnetic resonance imaging.

Authors:  George R Washko; Grace Parraga; Harvey O Coxson
Journal:  Respirology       Date:  2012-04       Impact factor: 6.424

2.  Dose and pulse sequence considerations for hyperpolarized (129)Xe ventilation MRI.

Authors:  Mu He; Scott H Robertson; S Sivaram Kaushik; Matthew S Freeman; Rohan S Virgincar; John Davies; Jane Stiles; William M Foster; H Page McAdams; Bastiaan Driehuys
Journal:  Magn Reson Imaging       Date:  2015-04-30       Impact factor: 2.546

3.  Validating the distribution of specific ventilation in healthy humans measured using proton MR imaging.

Authors:  Rui Carlos Sá; Amran K Asadi; Rebecca J Theilmann; Susan R Hopkins; G Kim Prisk; Chantal Darquenne
Journal:  J Appl Physiol (1985)       Date:  2014-02-06

Review 4.  Hyperpolarized and inert gas MRI: the future.

Authors:  Marcus J Couch; Barbara Blasiak; Boguslaw Tomanek; Alexei V Ouriadov; Matthew S Fox; Krista M Dowhos; Mitchell S Albert
Journal:  Mol Imaging Biol       Date:  2015-04       Impact factor: 3.488

5.  Imaging how and where we breathe oxygen: another Big Short?

Authors:  Dante P I Capaldi; Fumin Guo; Grace Parraga
Journal:  J Thorac Dis       Date:  2016-03       Impact factor: 2.895

6.  Longitudinal Computed Tomography and Magnetic Resonance Imaging of COPD: Thoracic Imaging Network of Canada (TINCan) Study Objectives.

Authors:  Miranda Kirby; Damien Pike; David G McCormack; Stephen Lam; Harvey O Coxson; Grace Parraga
Journal:  Chronic Obstr Pulm Dis       Date:  2014-09-25

7.  Signal-to-noise ratio, T2 , and T2* for hyperpolarized helium-3 MRI of the human lung at three magnetic field strengths.

Authors:  Peter Komlosi; Talissa A Altes; Kun Qing; Karen E Mooney; G Wilson Miller; Jaime F Mata; Eduard E de Lange; William A Tobias; Gordon D Cates; John P Mugler
Journal:  Magn Reson Med       Date:  2016-10-28       Impact factor: 4.668

8.  Assessment of the lung microstructure in patients with asthma using hyperpolarized 3He diffusion MRI at two time scales: comparison with healthy subjects and patients with COPD.

Authors:  Chengbo Wang; Talissa A Altes; John P Mugler; G Wilson Miller; Kai Ruppert; Jaime F Mata; Gordon D Cates; Larry Borish; Eduard E de Lange
Journal:  J Magn Reson Imaging       Date:  2008-07       Impact factor: 4.813

9.  Quantification of trapped gas with CT and 3 He MR imaging in a porcine model of isolated airway obstruction.

Authors:  Caterina Salito; Andrea Aliverti; David S Gierada; Gaetan Deslée; Richard A Pierce; Peter T Macklem; Jason C Woods
Journal:  Radiology       Date:  2009-07-31       Impact factor: 11.105

Review 10.  [Functional 3He-MRI of the lungs].

Authors:  K K Gast; U Wolf
Journal:  Radiologe       Date:  2009-08       Impact factor: 0.635

View more