Single-centre experience with coronary sinus lead stability and long-term pacing parameters.

Alan Bulava1, Jan Lukl.   

Abstract

AIMS: To compare both short- and long-term stability and pacing parameters of CS leads. Long-term maintenance of coronary sinus (CS) pacing lead position has not yet been assessed by serial X-ray digital imaging. METHODS AND
RESULTS: Using X-ray digital imaging in anteroposterior and left lateral views, we performed analysis of the CS lead position at the end of the implantation procedure, 48 h following implantation and after 12 months in 93 consecutive patients. Attain OTW leads, QuickSite leads and EasyTrak leads were implanted in 44, 12 and 37 cases, respectively. X-ray detectable late CS lead dislodgement was observed in 8 cases (8.6%) during 12-months follow-up. Dislodgment was once accompanied by loss of capture and need for repositioning. Another two major dislodgements occurred without any threshold change. Five (5.4%) minor dislocations occurred with either a decrease or an increase in pacing threshold. Left ventricular (LV) pacing threshold was changed by >or= 1 V after 12 months in 14 patients (15%) when compared to values 48 h after implantation. All but one case of >or= 1 V threshold change (either positive or negative) occurred without any radiological evidence of lead displacement. LV pacing threshold was significantly higher than RV pacing threshold at both baseline and during follow-up. Leads from all three manufacturers had comparable pacing thresholds 12 months following implantation.
CONCLUSION: The position of CS leads may change during 1-year follow-up. However, it rarely required reoperation in the selected group of patients. Long-term pacing parameters between different manufacturers are comparable. Increase in pacing threshold is not a reliable marker of CS lead dislodgement.

Entities:  

Mesh:

Year:  2007        PMID: 17507356     DOI: 10.1093/europace/eum082

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  4 in total

1.  3D dynamic position assessment of the coronary sinus lead in cardiac resynchronization therapy.

Authors:  Cristiana Corsi; Corrado Tomasi; Dario Turco; Massimo Margheri; Claudio Lamberti; Stefano Severi
Journal:  Med Biol Eng Comput       Date:  2011-06-29       Impact factor: 2.602

2.  Long-term prognosis of left ventricular lead.

Authors:  Seung-Jung Park; Il-Young Oh; Chang-Hwan Yoon; Hyo-Eun Park; Eue-Keun Choi; Gi-Byoung Nam; Kee-June Choi; You-Ho Kim; Yun-Shik Choi; Seil Oh
Journal:  J Korean Med Sci       Date:  2010-09-17       Impact factor: 2.153

3.  Right ventricular pacing and sensing function in high posterior septal and apical lead placement in cardiac resynchronization therapy.

Authors:  Hm Kristiansen; T Hovstad; G Vollan; S Faerestrand
Journal:  Indian Pacing Electrophysiol J       Date:  2012-01-31

4.  Coronary Sinus Stenting for the Management of Left Ventricular Lead Displacement during Resynchronization Therapy: A Report of Two Cases.

Authors:  Hassan Kamalzadeh; Shahrooz Yazdani; Mohammad Jalali
Journal:  J Tehran Heart Cent       Date:  2018-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.