Literature DB >> 17505093

Verification of cell irradiation dose deposition using a radiochromic film.

N Tomic1, M Gosselin, Jonathan F Wan, Uri Saragovi, E B Podgorsak, M Evans, S Devic.   

Abstract

We describe a technique for the MTT assay that irradiates all cells at once by a combination of couch movement and a step-and-shoot irradiation technique on a linear accelerator with 6 MV and 18 MV photon beams. In two experimental setups, we obtained maximum to minimum dose ranges of 10 for the constant MU/bin (monitor units per bin) setup and 20 for the variable MU/bin technique. The irradiation technique described is dose rate independent and it can be used on any teletherapy irradiation machine. We also employed radiochromic film dosimetry to verify dose delivered in each of the wells within the dish. It is shown that for the lowest doses, relative dose variation within wells reaches a value of 6%. We also demonstrated that the radiochromic film positioned below the 96-well plate does not underestimate dose deposited within each compartment by more than 2% due to the vertical dose gradient.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17505093     DOI: 10.1088/0031-9155/52/11/013

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Multichannel Film Dosimetry for Quality Assurance of Intensity Modulated Radiotherapy Treatment Plans Under 0.35 T Magnetic Field.

Authors:  Gorkem Gungor; Latif Korkmaz; Namik Kayalilar; Gokhan Aydin; Bulent Yapici; Teuta Zoto Mustafayev; Banu Atalar; Enis Ozyar
Journal:  Cureus       Date:  2020-03-20

2.  How air influences radiation dose deposition in multiwell culture plates: a Monte Carlo simulation of radiation geometry.

Authors:  Sebastia Sabater; Roberto Berenguer; Paloma Honrubia-Gomez; Miguel Rivera; Ana Nuñez; Esther Jimenez-Jimenez; Ana Martos; Carmen Ramirez-Castillejo
Journal:  J Radiat Res       Date:  2014-04-10       Impact factor: 2.724

3.  Evaluation of the uncertainty in an EBT3 film dosimetry system utilizing net optical density.

Authors:  Elsa Y León Marroquin; José A Herrera González; Miguel A Camacho López; José E Villarreal Barajas; Olivia A García-Garduño
Journal:  J Appl Clin Med Phys       Date:  2016-09-08       Impact factor: 2.102

4.  NVP-BSK805, an Inhibitor of JAK2 Kinase, Significantly Enhances the Radiosensitivity of Esophageal Squamous Cell Carcinoma in vitro and in vivo.

Authors:  Yuhui Hua; Weijia Wang; Xiaoli Zheng; Ling Yang; Hongjin Wu; Zhaoyang Hu; Ying Li; Jing Yue; Zhenzhen Jiang; Xiaoyan Zhang; Qiang Hou; Shixiu Wu
Journal:  Drug Des Devel Ther       Date:  2020-02-24       Impact factor: 4.162

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.