Literature DB >> 17505090

Quantitative validation of the 3D SAR profile of hyperthermia applicators using the gamma method.

Maarten de Bruijne1, Theodoros Samaras, Nicolas Chavannes, Gerard C van Rhoon.   

Abstract

For quality assurance of hyperthermia treatment planning systems, quantitative validation of the electromagnetic model of an applicator is essential. The objective of this study was to validate a finite-difference time-domain (FDTD) model implementation of the Lucite cone applicator (LCA) for superficial hyperthermia. The validation involved (i) the assessment of the match between the predicted and measured 3D specific absorption rate (SAR) distribution, and (ii) the assessment of the ratio between model power and real-world power. The 3D SAR distribution of seven LCAs was scanned in a phantom bath using the DASY4 dosimetric measurement system. The same set-up was modelled in SEMCAD X. The match between the predicted and the measured SAR distribution was quantified with the gamma method, which combines distance-to-agreement and dose difference criteria. Good quantitative agreement was observed: more than 95% of the measurement points met the acceptance criteria 2 mm/2% for all applicators. The ratio between measured and predicted power absorption ranged from 0.75 to 0.92 (mean 0.85). This study shows that quantitative validation of hyperthermia applicator models is feasible and is worth considering as a part of hyperthermia quality assurance procedures.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17505090     DOI: 10.1088/0031-9155/52/11/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Improved hyperthermia treatment control using SAR/temperature simulation and PRFS magnetic resonance thermal imaging.

Authors:  Zhen Li; Martin Vogel; Paolo F Maccarini; Vadim Stakhursky; Brian J Soher; Oana I Craciunescu; Shiva Das; Omar A Arabe; Williams T Joines; Paul R Stauffer
Journal:  Int J Hyperthermia       Date:  2010-11-11       Impact factor: 3.914

2.  Procedure for creating a three-dimensional (3D) model for superficial hyperthermia treatment planning.

Authors:  Marianne Linthorst; Tomas Drizdal; Hans Joosten; Gerard C van Rhoon; Jacoba van der Zee
Journal:  Strahlenther Onkol       Date:  2011-11-25       Impact factor: 3.621

3.  Miniature microwave applicator for murine bladder hyperthermia studies.

Authors:  Sara Salahi; Paolo F Maccarini; Dario B Rodrigues; Wiguins Etienne; Chelsea D Landon; Brant A Inman; Mark W Dewhirst; Paul R Stauffer
Journal:  Int J Hyperthermia       Date:  2012-06-12       Impact factor: 3.914

Review 4.  Simulation techniques in hyperthermia treatment planning.

Authors:  Margarethus M Paulides; Paul R Stauffer; Esra Neufeld; Paolo F Maccarini; Adamos Kyriakou; Richard A M Canters; Chris J Diederich; Jurriaan F Bakker; Gerard C Van Rhoon
Journal:  Int J Hyperthermia       Date:  2013-05-14       Impact factor: 3.914

5.  Simultaneous ThermoBrachytherapy: Electromagnetic Simulation Methods for Fast and Accurate Adaptive Treatment Planning.

Authors:  Ioannis Androulakis; Rob M C Mestrom; Miranda E M C Christianen; Inger-Karine K Kolkman-Deurloo; Gerard C van Rhoon
Journal:  Sensors (Basel)       Date:  2022-02-09       Impact factor: 3.576

6.  A Novel Framework for the Optimization of Simultaneous ThermoBrachyTherapy.

Authors:  Ioannis Androulakis; Rob M C Mestrom; Miranda E M C Christianen; Inger-Karine K Kolkman-Deurloo; Gerard C van Rhoon
Journal:  Cancers (Basel)       Date:  2022-03-10       Impact factor: 6.639

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.