Literature DB >> 17500471

Monte Carlo simulation of x-ray buildup factors of lead and its applications in shielding of diagnostic x-ray facilities.

Hedi Kharrati1, Amel Agrebi, Mohamed-Karim Karaoui.   

Abstract

X-ray buildup factors of lead in broad beam geometry for energies from 15 to 150 keV are determined using the general purpose Monte Carlo N-particle radiation transport computer code (MCNP4C). The obtained buildup factors data are fitted to a modified three parameter Archer et al. model for ease in calculating the broad beam transmission with computer at any tube potentials/ filters combinations in diagnostic energies range. An example for their use to compute the broad beam transmission at 70, 100, 120, and 140 kVp is given. The calculated broad beam transmission is compared to data derived from literature, presenting good agreement. Therefore, the combination of the buildup factors data as determined and a mathematical model to generate x-ray spectra provide a computationally based solution to broad beam transmission for lead barriers in shielding x-ray facilities.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17500471     DOI: 10.1118/1.2710333

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  2 in total

1.  Geant4 Simulation of Gamma-Ray Transmission Buildup Factors for Human Tissues.

Authors:  Abdulrahman A Alfuraih; Omrane M Kadri
Journal:  Dose Response       Date:  2022-03-01       Impact factor: 2.658

2.  Evaluation of the occupational doses of interventional radiologists.

Authors:  Gerritjan Kuipers; Xandra L Velders; Robbert J de Winter; Jim A Reekers; Jan J Piek
Journal:  Cardiovasc Intervent Radiol       Date:  2008-02-12       Impact factor: 2.740