Literature DB >> 17499206

Porous orbital implants, wraps, and PEG placement in the pediatric population after enucleation.

Jia-Kang Wang1, Shu Lang Liao, Luke L K Lin, Shine C S Kao, Hsiao-Sen Tseng.   

Abstract

PURPOSE: To investigate complications of various porous orbital implants and wrapping materials in the pediatric population after enucleation.
DESIGN: A retrospective, comparative, nonrandomized study.
METHODS: Between November 1992 and November 2006, patients younger than 15 years old were collected for study participation. They underwent enucleation with porous orbital implants primarily or secondarily at National Taiwan University Hospital. The authors used the hydroxyapatite (HA), Medpor, and Bioceramic orbital implant. The HA implant was wrapped with four different materials: donor sclera, Lyodura, porcine sclera, and Vicryl mesh. A part of HA implants and all bioceramic implants were wrapped with Vicryl mesh, added anteriorly with scleral patch grafts. All Medpor implants were unwrapped.
RESULTS: Forty-seven cases had more than a two-year follow-up. The exposure rates according to implants and wraps were: donor sclera-wrapped HA (two of nine, 22%), porcine sclera-wrapped HA (three of three, 100%), Vicryl mesh-wrapped HA (one of five, 20%), and unwrapped Medpor (one of four, 25%). No exposure was found in four Lyodura-wrapped HA implants, and 22 Vicryl mesh-wrapped HA and Bioceramic implants with anteriorly scleral coating. The exposure rate was lower in cases with implants wrapped by our method and Lyodura than in those with implants wrapped by other materials (P < .001). Of 47 patients, 20 (42.5%) were fitted with peg-coupled prostheses and all had good prosthetic movements subjectively.
CONCLUSIONS: Different types of implants and wraps resulted in various exposure rates in the pediatric population. The modified wrapping technique may prevent porous implants from exposure in children.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17499206     DOI: 10.1016/j.ajo.2007.03.042

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  3 in total

1.  Comparative study of modified and conventional secondary hydroxyapatite orbital implantations.

Authors:  Yong Zhao; Mao-Nian Zhang; Yun-Xian Gao; Xiao-Wei Gao; Bing Ren
Journal:  Int J Ophthalmol       Date:  2013-10-18       Impact factor: 1.779

2.  The effect of cancer therapies on pediatric anophthalmic sockets.

Authors:  Yevgeniy Shildkrot; Maria Kirzhner; Barrett G Haik; Ibrahim Qaddoumi; Carlos Rodriguez-Galindo; Matthew W Wilson
Journal:  Ophthalmology       Date:  2011-12       Impact factor: 12.079

3.  Enucleation and evisceration: indications, complications and clinicopathological correlations.

Authors:  Ali Kord Valeshabad; Masood Naseripour; Rajab Asghari; Seyed Hamid Parhizgar; Seyed Ehsan Parhizgar; Mohammad Taghvaei; Shahin Miri
Journal:  Int J Ophthalmol       Date:  2014-08-18       Impact factor: 1.779

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.