Literature DB >> 17498913

Combination blue dye sentinel lymph node biopsy and axillary node sampling: the Edinburgh experience.

U Chetty1, P K Y Chin, P H S Soon, W Jack, J St J Thomas.   

Abstract

AIMS: The sentinel node biopsy technique which is being increasingly used to stage breast cancers has limitations regarding not being able to find the blue hot node in about 5% of cases and false negative results in 7% of cases. It has been suggested this is probably due to tumour blocking the lymphatic channels. The four node sampling technique is dependent on the surgeon's ability to find abnormal palpable nodes in the axilla without visual or radioactive signal directions. We have combined the two techniques with the expectation to improve the results.
METHOD: The study evaluates the combined technique in 434 patients with early breast cancer in a single centre.
RESULTS: A blue sentinel node was identified in 394 of 434 cases (91.7%), the false negative rate was 2.4%. Thirty six patients had no sentinel node identified. Thirteen of these had positive nodes in the node sample.
CONCLUSION: Axillary node sampling adds to the accuracy of the sentinel node biopsy using blue dye. Pathological features suggest that the principal cause of false negative sentinel node biopsy is due to blocking of the lymphatic channels by the cancer.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17498913     DOI: 10.1016/j.ejso.2007.02.008

Source DB:  PubMed          Journal:  Eur J Surg Oncol        ISSN: 0748-7983            Impact factor:   4.424


  5 in total

Review 1.  Current trends in breast surgery.

Authors:  Amit Goyal
Journal:  Indian J Surg Oncol       Date:  2012-08-03

2.  Management of the axilla in patients with breast cancer.

Authors:  Amit Goyal
Journal:  Indian J Surg       Date:  2010-01-13       Impact factor: 0.656

3.  Efficacy of Periareolar Versus Peritumoral Injection of TC99-Labelled Sulphur Colloid and Methylene Blue Dye for Detection of Sentinel Lymph Node in Patients with Early Breast Cancer: a Comparative Study.

Authors:  Chanchal Malhotra; Richa Pawar; Sanjeev Patni; Mitesh Kaushik; Nivedita Sharma
Journal:  Indian J Surg Oncol       Date:  2020-09-25

4.  Accuracy of individual descriptors and grading of nodal involvement by axillary ultrasound in patients of breast cancer.

Authors:  Navneet Kaur; Pradeep Sharma; Akhil Garg; Anupama Tandon
Journal:  Int J Breast Cancer       Date:  2013-12-19

Review 5.  The sentinel node in breast cancer.

Authors:  Conor D Collins
Journal:  Cancer Imaging       Date:  2008-10-04       Impact factor: 3.909

  5 in total