Literature DB >> 17497981

Nerve stimulation in thyroid surgery: is it really useful?

Thorbjorn J Loch-Wilkinson1, Peter L H Stalberg, Stan B Sidhu, Mark S Sywak, James F Wilkinson, Leigh W Delbridge.   

Abstract

BACKGROUND: Monitoring of the recurrent laryngeal nerve (RLN) has been claimed in some studies to reduce rates of nerve injury during thyroid surgery compared with anatomical dissection and visual identification of the RLN alone, whereas other studies have found no benefit. Continuous monitoring with endotracheal electrodes is expensive whereas discontinuous monitoring by laryngeal palpation with nerve stimulation is a simple and inexpensive technique. This study aimed to assess the value of nerve stimulation with laryngeal palpation as a means of identifying and assessing the function of the RLN and external branch of the superior laryngeal nerve (EBSLN) during thyroid surgery.
METHODS: This was a prospective case series comprising 50 consecutive patients undergoing total thyroidectomy providing 100 RLN and 100 EBSLN for examination. All patients underwent preoperative and postoperative vocal cord and voice assessment by an independent ear, nose and throat surgeon, laryngeal examination at extubation and all were asked to complete a postoperative dysphagia score sheet. Dysphagia scores in the study group were compared with a control group (n = 20) undergoing total thyroidectomy without nerve stimulation.
RESULTS: One hundred of 100 (100%) RLN were located without the use of the nerve stimulator. A negative twitch response occurred in seven (7%) RLN stimulated (two bilateral, three unilateral). Postoperative testing, however, only showed one true unilateral RLN palsy postoperatively (1%), which recovered in 7 weeks giving six false-positive and one true-positive results. Eighty-six of 100 (86%) EBSLN were located without the nerve stimulator. Thirteen of 100 (13%) EBSLN could not be identified and 1 of 100 (1%) was located with the use of the nerve stimulator. Fourteen per cent of EBSLN showed no cricothyroid twitch on EBSLN stimulation. Postoperative vocal function in these patients was normal. There were no instances of equipment malfunction. Dysphagia scores did not differ significantly between the study and control groups.
CONCLUSION: Use of a nerve stimulator did not aid in anatomical dissection of the RLN and was useful in identifying only one EBSLN. Discontinuous nerve monitoring by stimulation during total thyroidectomy confers no obvious benefit for the experienced surgeon in nerve identification, functional testing or injury prevention.

Entities:  

Mesh:

Year:  2007        PMID: 17497981     DOI: 10.1111/j.1445-2197.2007.04065.x

Source DB:  PubMed          Journal:  ANZ J Surg        ISSN: 1445-1433            Impact factor:   1.872


  30 in total

1.  Visualization versus neuromonitoring of recurrent laryngeal nerves during thyroidectomy: what about the costs?

Authors:  Gianlorenzo Dionigi; Alessandro Bacuzzi; Luigi Boni; Stefano Rausei; Francesca Rovera; Renzo Dionigi
Journal:  World J Surg       Date:  2012-04       Impact factor: 3.352

2.  Is Nerve Monitoring Required in Total Thyroidectomy? Cerrahpasa Experience.

Authors:  Serkan Teksoz; Yusuf Bukey; Murat Ozcan; Akif Enes Arikan; Ates Ozyegin
Journal:  Indian J Surg       Date:  2013-01-31       Impact factor: 0.656

3.  Complications to thyroid surgery: results as reported in a database from a multicenter audit comprising 3,660 patients.

Authors:  A Bergenfelz; S Jansson; A Kristoffersson; H Mårtensson; E Reihnér; G Wallin; I Lausen
Journal:  Langenbecks Arch Surg       Date:  2008-07-17       Impact factor: 3.445

4.  Electromyographic response persists after peripheral transection: endorsement of current concepts in recurrent laryngeal nerve monitoring in a porcine model.

Authors:  Torsten Birkholz; Andrea Irouschek; Dirk Labahn; Peter Klein; Joachim Schmidt
Journal:  Langenbecks Arch Surg       Date:  2009-11-25       Impact factor: 3.445

5.  Neuromonitoring and video-assisted thyroidectomy: a prospective, randomized case-control evaluation.

Authors:  Gianlorenzo Dionigi; Luigi Boni; Francesca Rovera; Alessandro Bacuzzi; Renzo Dionigi
Journal:  Surg Endosc       Date:  2008-09-21       Impact factor: 4.584

6.  Implementation of systematic neuromonitoring training for thyroid surgery.

Authors:  G Dionigi; A Bacuzzi; M Barczynski; A Biondi; L Boni; F Y Chiang; H Dralle; G W Randolph; S Rausei; R Sacco; A Sitges-Serra
Journal:  Updates Surg       Date:  2011-07-22

7.  Surgical anatomy of the external branch of the superior laryngeal nerve: a systematic review and meta-analysis.

Authors:  Isaac Cheruiyot; Vincent Kipkorir; Brandon Michael Henry; Jeremiah Munguti; Roberto Cirocchi; Paul Odula; Linda M Wong; Beda Olabu; Jerzy Walocha
Journal:  Langenbecks Arch Surg       Date:  2018-11-14       Impact factor: 3.445

Review 8.  Differentiated thyroid cancer-personalized therapies to prevent overtreatment.

Authors:  Markus Luster; Theresia Weber; Frederik A Verburg
Journal:  Nat Rev Endocrinol       Date:  2014-07-01       Impact factor: 43.330

Review 9.  Opportunities and challenges of intermittent and continuous intraoperative neural monitoring in thyroid surgery.

Authors:  Rick Schneider; Andreas Machens; Gregory W Randolph; Dipti Kamani; Kerstin Lorenz; Henning Dralle
Journal:  Gland Surg       Date:  2017-10

10.  Minimally invasive video-assisted thyroidectomy and parathyroidectomy with intraoperative recurrent laryngeal nerve monitoring.

Authors:  Emad Kandil; Shafik N Wassef; Haytham Alabbas; Paul L Freidlander
Journal:  Int J Otolaryngol       Date:  2010-02-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.