Literature DB >> 1749667

Cerebral-blood-flow-velocity measurements in neonates: technique and interobserver reliability.

A Ohlsson1, K Fong, M L Ryan, L Yap, J D Smith, A T Shennan, P Glanc.   

Abstract

The interobserver reliability for absolute cerebral-blood-flow-velocity measurements by colour and duplex Doppler sonography was tested in 32 neonates with a mean birth weight of 1489 (SD 644) g, and a gestational age of 29.9 (SD 3.5) weeks. Using standardized technique, two observers recorded on videotape, the Doppler spectrum of the anterior cerebral artery, the intracranial internal carotid artery and the middle cerebral artery. Peak systolic flow, end diastolic flow, mean flow velocity, resistive index and pulsatility index were computed from 3 consecutive waveforms by each observer. The estimates of interobserver reliability using the intraclass correlation coefficient of the examiners varied from 0.95 to 1.00. Therefore, cerebral blood flow velocity can be reliably measured in premature infants.

Entities:  

Mesh:

Year:  1991        PMID: 1749667     DOI: 10.1007/bf02026666

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  12 in total

1.  Reproducibility of cerebral artery Doppler measurements.

Authors:  B Moorthy; P R Colditz; K N Ives; D G Rees; W G van't Hoff; P L Hope
Journal:  Arch Dis Child       Date:  1990-07       Impact factor: 3.791

2.  Intracranial blood flow: quantification with duplex Doppler and color Doppler flow US.

Authors:  G A Taylor; B L Short; L K Walker; R J Traystman
Journal:  Radiology       Date:  1990-07       Impact factor: 11.105

3.  Pulsed Doppler sonographic measurement of normal values for the flow velocities in the intracranial arteries of healthy newborns.

Authors:  K H Deeg; T Rupprecht
Journal:  Pediatr Radiol       Date:  1989

4.  Color Doppler imaging of intracranial vessels in the neonate.

Authors:  W S Wong; J S Tsuruda; R L Liberman; A Chirino; J F Vogt; E Gangitano
Journal:  AJR Am J Roentgenol       Date:  1989-05       Impact factor: 3.959

Review 5.  Intraclass correlations: uses in assessing rater reliability.

Authors:  P E Shrout; J L Fleiss
Journal:  Psychol Bull       Date:  1979-03       Impact factor: 17.737

6.  [Doppler sonographic measurement of normal values of flow velocities in the internal carotid artery of premature infants, newborn infants and infants].

Authors:  K H Deeg; T H Rupprecht
Journal:  Monatsschr Kinderheilkd       Date:  1988-04       Impact factor: 0.323

7.  Sample size requirements for reliability studies.

Authors:  A Donner; M Eliasziw
Journal:  Stat Med       Date:  1987-06       Impact factor: 2.373

8.  An appraisal of techniques for studying cerebral circulation in the newborn. Report of a mini-symposium held in September 1982.

Authors:  P Rolfe; B Persson; R Zetterström
Journal:  Acta Paediatr Scand Suppl       Date:  1983

9.  Morphologic variations in periventricular leukomalacia.

Authors:  R W Leech; E C Alvord
Journal:  Am J Pathol       Date:  1974-03       Impact factor: 4.307

10.  Neonatal brain: color Doppler imaging. Part I. Technique and vascular anatomy.

Authors:  D G Mitchell; D Merton; L Needleman; A B Kurtz; B B Goldberg; D Levy; M D Rifkin; R G Pennell; M Vilaro; O Baltarowich
Journal:  Radiology       Date:  1988-05       Impact factor: 11.105

View more
  3 in total

1.  Does endothelin-1 reduce superior mesenteric artery blood flow velocity in preterm neonates?

Authors:  F J Weir; A Ohlsson; K Fong; K Amankwah; F Coceani
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1999-03       Impact factor: 5.747

2.  The effect of dexamethasone on time averaged mean velocity in the middle cerebral artery in very low birth weight infants.

Authors:  A Ohlsson; J Bottu; J Govan; M L Ryan; T Myhr; K Fong
Journal:  Eur J Pediatr       Date:  1994-05       Impact factor: 3.183

3.  A Preliminary Study of Neonatal Cranial Venous System by Color Doppler.

Authors:  Lu Yang Liu; Jin Ling Hong; Chang Jun Wu
Journal:  Biomed Res Int       Date:  2019-04-28       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.