Literature DB >> 17496492

Reproducibility of transthoracic echocardiography in small animals using clinical equipment.

Gerald H Wasmeier1, Ivan Melnychenko, Jens-Uwe Voigt, Wolfram H Zimmermann, Thomas Eschenhagen, Nico Schineis, Udo Reulbach, Frank A Flachskampf, Werner G Daniel, Uwe Nixdorff.   

Abstract

OBJECTIVE: Transthoracic echocardiography has been employed to assess left ventricular dimensions and function in small animals. The aim of this study was to identify the limits of transthoracic echocardiography in a commonly used Wistar rat model by assessing intraobserver variability, interobserver variability, and day-to-day variability of examinations implying registrations and measurements.
METHODS: Twenty male adult Wistar rats (body weight 496+/-52 g) were examined under volatile isoflurane anesthesia (heart rate 302+/-26 bpm) by transthoracic echocardiography (Sonos 7500; Philips) with a 15 MHz-transducer. For calculation of intraobserver variability, examinations were repeated by the same examiner and for interobserver variability, examinations were performed independently by two investigators. For day-to-day variability, examinations were repeated 14 days later. Left ventricular diameters and areas were analyzed in parasternal short axis and in a modified parasternal long axis. Fractional shortening, area shortening, ejection fraction, stroke volume, and cardiac output were calculated.
RESULTS: Left ventricular end-diastolic diameter was 8.9+/-0.6 mm, fractional shortening 39.0+/-5.3%, area shortening 59.6+/-6.1%, ejection fraction 83.3+/-5.1%, stroke volume 0.24+/-0.06 ml, and cardiac output 72.9+/-20.6 ml/min. Intraobserver variability of left ventricular end-diastolic diameter, fractional shortening, area shortening, and ejection fraction was less than 10%, increasing to 19% for stroke volume and cardiac output. Interobserver variability of left ventricular end-diastolic diameter, fractional shortening, area shortening, ejection fraction was less than 13%, increasing to 23% for stroke volume and 25% for cardiac output. Day-to-day variability of left ventricular end-diastolic diameter, area shortening, ejection fraction was less than 11% whereas for stroke volume it was 21% and for cardiac output it was 22%. F-ratio test comparing investigated variabilities did not reveal significant differences.
CONCLUSIONS: M-mode and two-dimensional echocardiography in large rats by clinically common high-end ultrasound systems can be assessed reliably. Parameters of global left ventricular performance like stroke volume and cardiac output could not be assessed with similar reliability.

Entities:  

Mesh:

Year:  2007        PMID: 17496492     DOI: 10.1097/MCA.0b013e3280d5a7e3

Source DB:  PubMed          Journal:  Coron Artery Dis        ISSN: 0954-6928            Impact factor:   1.439


  8 in total

1.  Isoproterenol induces primary loss of dystrophin in rat hearts: correlation with myocardial injury.

Authors:  Erica C Campos; Minna M D Romano; Cibele M Prado; Marcos A Rossi
Journal:  Int J Exp Pathol       Date:  2008-10       Impact factor: 1.925

2.  RGDfK-Peptide Modified Alginate Scaffold for Cell Transplantation and Cardiac Neovascularization.

Authors:  Hugo P Sondermeijer; Piotr Witkowski; Tetsunori Seki; Arnoud van der Laarse; Silviu Itescu; Mark A Hardy
Journal:  Tissue Eng Part A       Date:  2017-11-13       Impact factor: 3.845

3.  Effects of injectable anesthetic combinations on left ventricular function and cardiac morphology in Sprague-Dawley rats.

Authors:  Carla F Sabatini; M Lynne O'Sullivan; James E Valcour; William Sears; Ron J Johnson
Journal:  J Am Assoc Lab Anim Sci       Date:  2013-01       Impact factor: 1.232

4.  Conductance catheter measurement and effect of different anesthetics in a rat model of postresuscitation myocardial dysfunction.

Authors:  Jürgen Knapp; Peter Teschendorf; Eberhard Scholz; Joachim Roewer; Nicolai Russ; Bernd W Böttiger; Erik Popp
Journal:  J Am Assoc Lab Anim Sci       Date:  2014-07       Impact factor: 1.232

5.  AVP-induced increase in AQP2 and p-AQP2 is blunted in heart failure during cardiac remodeling and is associated with decreased AT1R abundance in rat kidney.

Authors:  Sophie Constantin Lütken; Jørgen Frøkiær; Søren Nielsen
Journal:  PLoS One       Date:  2015-02-06       Impact factor: 3.240

6.  Echocardiographic evaluation of cardiac function in ischemic rats: value of m-mode echocardiography.

Authors:  Amir Darbandi Azar; Fatemeh Tavakoli; Hassan Moladoust; Asghar Zare; Anita Sadeghpour
Journal:  Res Cardiovasc Med       Date:  2014-11-01

7.  Use of echocardiography reveals reestablishment of ventricular pumping efficiency and partial ventricular wall motion recovery upon ventricular cryoinjury in the zebrafish.

Authors:  Juan Manuel González-Rosa; Gabriela Guzmán-Martínez; Inês João Marques; Héctor Sánchez-Iranzo; Luis Jesús Jiménez-Borreguero; Nadia Mercader
Journal:  PLoS One       Date:  2014-12-22       Impact factor: 3.240

8.  Monitoring the reproductive activity in captive bred female ball pythons (P. regius) by ultrasound evaluation and noninvasive analysis of faecal reproductive hormone (progesterone and 17β-estradiol) metabolites trends.

Authors:  Mara Bertocchi; Igor Pelizzone; Enrico Parmigiani; Patrizia Ponzio; Elisabetta Macchi; Federico Righi; Nicola Di Girolamo; Enrico Bigliardi; Laura Denti; Carla Bresciani; Francesco Di Ianni
Journal:  PLoS One       Date:  2018-06-27       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.