Literature DB >> 17494662

MR angiography of dural arteriovenous fistulas: diagnosis and follow-up after treatment using a time-resolved 3D contrast-enhanced technique.

S Meckel1, M Maier, D San Millan Ruiz, H Yilmaz, K Scheffler, E-W Radue, S G Wetzel.   

Abstract

BACKGROUND AND
PURPOSE: Digital subtraction angiography (DSA) is the method of reference for imaging of dural arteriovenous fistula (DAVF). The goal of this study was to analyze the value of different MR images including 3D contrast-enhanced MR angiography (MRA) with a high temporal resolution in diagnostic and follow-up imaging of DAVFs.
MATERIALS AND METHODS: A total of 18 MR/MRA examinations from 14 patients with untreated (n=9) and/or treated (n=9) DAVFs were evaluated. Two observers assessed all MR and MRA investigations for signs indicating the presence of a DAVF, for fistula characteristics such as fistula grading, location of fistulous point, and fistula obliteration after treatment. All results were compared with DSA findings.
RESULTS: On time-resolved 3D contrast-enhanced (TR 3D) MRA, the side and presence of all patent fistulas (n=13) were correctly indicated, and no false-positive findings were observed in occluded DAVFs (n=5). Grading of fistulas with this imaging technique was correct in 77% and 85% of patent fistulas for both readers, respectively. On T2-weighted images, signs indicative of a DAVF were encountered only in fistulas with cortical venous reflux (56%), whereas on 3D time-of-flight (TOF) MRA, most fistulas (88%) were correctly detected. In complete fistula occlusion, false-positive findings were encountered on both T2-weighted images and on TOF MRA images.
CONCLUSION: In this study, TR 3D MRA proved reliable in detecting DAVFs and suitable for follow-up imaging. The technique allowed--within limitations--to grade DAVFs. Although 3D TOF MRA can depict signs of DAVFs, its value for follow-up imaging is limited.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17494662      PMCID: PMC8134326     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  28 in total

1.  MR digital subtraction angiography for the assessment of cranial arteriovenous malformations and fistulas.

Authors:  S Aoki; T Yoshikawa; M Hori; A Nanbu; H Kumagai; Y Nishiyama; H Nukui; T Araki
Journal:  AJR Am J Roentgenol       Date:  2000-08       Impact factor: 3.959

2.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

3.  Combining endovascular and neurosurgical treatments of high-risk dural arteriovenous fistulas in the lateral sinus and the confluence of the sinuses.

Authors:  K Goto; P Sidipratomo; N Ogata; T Inoue; H Matsuno
Journal:  J Neurosurg       Date:  1999-02       Impact factor: 5.115

4.  Dural arteriovenous fistulae: noninvasive diagnosis with dynamic MR digital subtraction angiography.

Authors:  Stuart C Coley; Charles A J Romanowski; Timothy J Hodgson; Paul D Griffiths
Journal:  AJNR Am J Neuroradiol       Date:  2002-03       Impact factor: 3.825

5.  Evaluation of the intracranial dural sinuses with a 3D contrast-enhanced MP-RAGE sequence: prospective comparison with 2D-TOF MR venography and digital subtraction angiography.

Authors:  L Liang; Y Korogi; T Sugahara; M Onomichi; Y Shigematsu; D Yang; M Kitajima; Y Hiai; M Takahashi
Journal:  AJNR Am J Neuroradiol       Date:  2001-03       Impact factor: 3.825

6.  Dynamic 3D MR angiography of intra- and extracranial vascular malformations at 3T: a technical note.

Authors:  S Ziyeh; R Strecker; A Berlis; J Weber; J Klisch; I Mader
Journal:  AJNR Am J Neuroradiol       Date:  2005-03       Impact factor: 3.825

7.  MR imaging findings of intracranial dural arteriovenous fistulas: relations with venous drainage patterns.

Authors:  Bae Ju Kwon; Moon Hee Han; Hyun-Seung Kang; Kee-Hyun Chang
Journal:  AJNR Am J Neuroradiol       Date:  2005 Nov-Dec       Impact factor: 3.825

8.  Time-resolved projection MRA: clinical application in intracranial vascular malformations.

Authors:  J Klisch; R Strecker; J Hennig; M Schumacher
Journal:  Neuroradiology       Date:  2000-02       Impact factor: 2.804

9.  Intracranial dural arteriovenous fistulas: evaluation with combined 3D time-of-flight MR angiography and MR digital subtraction angiography.

Authors:  Kyo Noguchi; Elias R Melhem; Tadayoshi Kanazawa; Michiya Kubo; Naoya Kuwayama; Hikaru Seto
Journal:  AJR Am J Roentgenol       Date:  2004-01       Impact factor: 3.959

10.  Three-dimensional MR digital subtraction angiography using parallel imaging and keyhole data sampling in cerebrovascular diseases: initial experience.

Authors:  Kazuhiro Tsuchiya; Chinatsu Aoki; Akira Fujikawa; Junichi Hachiya
Journal:  Eur Radiol       Date:  2004-03-20       Impact factor: 5.315

View more
  36 in total

1.  Time-resolved MR angiography of the intracranial venous system: an alternative MR venography technique.

Authors:  Hasan Yiğit; Aynur Turan; Elif Ergün; Pınar Koşar; Uğur Koşar
Journal:  Eur Radiol       Date:  2011-11-20       Impact factor: 5.315

2.  Quality-evaluation scheme for cerebral time-resolved 3D contrast-enhanced MR angiography techniques.

Authors:  H Raoult; J-C Ferré; X Morandi; B Carsin-Nicol; M Carsin; M Cuggia; M Law; J-Y Gauvrit
Journal:  AJNR Am J Neuroradiol       Date:  2010-05-06       Impact factor: 3.825

3.  Orbital color Doppler ultrasound as noninvasive tool in the diagnosis of anterior-draining carotid-cavernous fistula.

Authors:  Massimo Venturini; Giulia Cristel; Stefania Bianchi Marzoli; Franco Simionato; Giulia Agostini; Piero Barboni; Francesco De Cobelli; Andrea Falini; Francesco Bandello; Alessandro Del Maschio
Journal:  Radiol Med       Date:  2015-12-06       Impact factor: 3.469

4.  Now you see it, now you don't--the hidden life of cerebral dural arteriovenous fistulae.

Authors:  Gabriele Brasse; Henrik J Roth; Dominik Fritzsch; Rainer Scheid
Journal:  Neuroradiology       Date:  2008-12-13       Impact factor: 2.804

5.  Efficacy of DynaCT digital angiography in the detection of the fistulous point of dural arteriovenous fistulas.

Authors:  T Hiu; N Kitagawa; M Morikawa; K Hayashi; N Horie; Y Morofuji; K Suyama; I Nagata
Journal:  AJNR Am J Neuroradiol       Date:  2009-02-12       Impact factor: 3.825

6.  Susceptibility-weighted imaging in carotido-cavernous fistulas. A case control study.

Authors:  Kamble Jayaprakash Harsha; Ram Shenoy Basti; Chandrasekharan Kesavadas; Bejoy Thomas
Journal:  Interv Neuroradiol       Date:  2013-12-18       Impact factor: 1.610

7.  Cerebral venous thrombosis: diagnostic accuracy of combined, dynamic and static, contrast-enhanced 4D MR venography.

Authors:  S Meckel; C Reisinger; J Bremerich; D Damm; M Wolbers; S Engelter; K Scheffler; S G Wetzel
Journal:  AJNR Am J Neuroradiol       Date:  2009-11-05       Impact factor: 3.825

8.  Evaluation of dural arteriovenous fistulas of cavernous sinus before and after endovascular treatment using time-resolved MR angiography.

Authors:  Shigeyuki Sakamoto; Masaaki Shibukawa; Yoshihiro Kiura; Toshinori Matsushige; Nobukazu Abe; Kaoru Kurisu
Journal:  Neurosurg Rev       Date:  2010-02-25       Impact factor: 3.042

9.  Optimal MRI sequence for identifying occlusion location in acute stroke: which value of time-resolved contrast-enhanced MRA?

Authors:  A Le Bras; H Raoult; J-C Ferré; T Ronzière; J-Y Gauvrit
Journal:  AJNR Am J Neuroradiol       Date:  2015-03-12       Impact factor: 3.825

10.  Evaluation of dural arteriovenous fistulas with 4D contrast-enhanced MR angiography at 3T.

Authors:  S Nishimura; T Hirai; A Sasao; M Kitajima; M Morioka; Y Kai; Y Omori; T Okuda; R Murakami; H Fukuoka; K Awai; J-I Kuratsu; Y Yamashita
Journal:  AJNR Am J Neuroradiol       Date:  2009-10-15       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.