Literature DB >> 17493877

Safety and tolerability of repetitive transcranial magnetic stimulation in patients with epilepsy: a review of the literature.

Erica Hyunji Bae1, Lara M Schrader, Katsuyuki Machii, Miguel Alonso-Alonso, James J Riviello, Alvaro Pascual-Leone, Alexander Rotenberg.   

Abstract

Repetitive transcranial magnetic stimulation (rTMS) is emerging as a new therapeutic tool in epilepsy, where it can be used to suppress seizures or treat comorbid conditions such as mood disorder. However, as rTMS carries a risk of inducing seizures among other adverse events, its safety and tolerability in the population with epilepsy warrant distinct consideration, as this group is especially seizure-prone. Accordingly, we performed a review of the literature to estimate the risk of seizures and other adverse events associated with rTMS in patients with epilepsy. We performed an English-language literature search, and reviewed all studies published from January 1990 to February 2007 in which patients with epilepsy were treated with rTMS, and complemented the literature search with personal correspondence with authors when necessary. We identified 30 publications that described patients with epilepsy who underwent rTMS, and noted total number of relevant subjects, medication usage, incidence of adverse events, and rTMS parameters including stimulus frequency, number of stimuli, train duration, intertrain interval, coil type, and stimulation sites. The data were analyzed for adverse events related to rTMS. Crude per-subject risk, as well as per-subject mean risk weighted by sample size and risk per 1000 stimuli weighted by number of stimuli in each study, were computed for seizures and for other adverse events. Adverse events or lack thereof was reported in 26 studies (n=280 subjects). Adverse events attributed to rTMS were generally mild and occurred in 17.1% of subjects. Headache was most common, occurring in 9.6%. The most serious adverse event was seizure during treatment, which occurred in four patients (1.4% crude per-subject risk). All but one case were the patients' typical seizures with respect to duration and semiology, and were associated with low-frequency rTMS. A single case of an atypical seizure appearing to arise from the region of stimulation during high-frequency rTMS is reported. No rTMS-related episodes of status epilepticus were reported. We cautiously conclude that the risk of seizure in patients with epilepsy undergoing rTMS is small, and the risk of other mild adverse events is comparable to that seen when rTMS is used to treat other diseases. Status epilepticus or life-threatening seizures have not been reported in patients undergoing rTMS treatment. rTMS thus appears to be nearly as safe in patients with epilepsy as in nonepileptic individuals, and warrants further investigation as a therapy in this population.

Entities:  

Mesh:

Year:  2007        PMID: 17493877     DOI: 10.1016/j.yebeh.2007.03.004

Source DB:  PubMed          Journal:  Epilepsy Behav        ISSN: 1525-5050            Impact factor:   2.937


  37 in total

1.  Effects of 30Hz θ burst transcranial magnetic stimulation on the primary motor cortex.

Authors:  Steve W Wu; Nasrin Shahana; David A Huddleston; Donald L Gilbert
Journal:  J Neurosci Methods       Date:  2012-05-22       Impact factor: 2.390

Review 2.  Safety of Transcranial Magnetic Stimulation in Children: A Systematic Review of the Literature.

Authors:  Corey H Allen; Benzi M Kluger; Isabelle Buard
Journal:  Pediatr Neurol       Date:  2017-01-04       Impact factor: 3.372

3.  This is your brain on drugs: predicting anticonvulsant effect using transcranial stimulation.

Authors:  Scott Mintzer
Journal:  Epilepsy Curr       Date:  2011-01       Impact factor: 7.500

Review 4.  Use of transcranial magnetic stimulation to influence behavior.

Authors:  Benzi M Kluger; William J Triggs
Journal:  Curr Neurol Neurosci Rep       Date:  2007-11       Impact factor: 5.081

Review 5.  Safety, ethical considerations, and application guidelines for the use of transcranial magnetic stimulation in clinical practice and research.

Authors:  Simone Rossi; Mark Hallett; Paolo M Rossini; Alvaro Pascual-Leone
Journal:  Clin Neurophysiol       Date:  2009-10-14       Impact factor: 3.708

6.  Safety study of 50 Hz repetitive transcranial magnetic stimulation in patients with Parkinson's disease.

Authors:  David H Benninger; Mikhail Lomarev; Eric M Wassermann; Grisel Lopez; Elise Houdayer; Rebecca E Fasano; Nguyet Dang; Mark Hallett
Journal:  Clin Neurophysiol       Date:  2009-03-14       Impact factor: 3.708

Review 7.  Safety of transcranial magnetic stimulation in Parkinson's disease: a review of the literature.

Authors:  Matthew Vonloh; Robert Chen; Benzi Kluger
Journal:  Parkinsonism Relat Disord       Date:  2013-03-07       Impact factor: 4.891

Review 8.  A review of combined TMS-EEG studies to characterize lasting effects of repetitive TMS and assess their usefulness in cognitive and clinical neuroscience.

Authors:  Gregor Thut; Alvaro Pascual-Leone
Journal:  Brain Topogr       Date:  2009-10-28       Impact factor: 3.020

9.  Transcranial magnetic stimulation for refractory focal status epilepticus in the intensive care unit.

Authors:  Anli Liu; Trudy Pang; Susan Herman; Alvaro Pascual-Leone; Alexander Rotenberg
Journal:  Seizure       Date:  2013-07-19       Impact factor: 3.184

Review 10.  Plasticity in neurological disorders and challenges for noninvasive brain stimulation (NBS).

Authors:  Gary W Thickbroom; Frank L Mastaglia
Journal:  J Neuroeng Rehabil       Date:  2009-02-17       Impact factor: 4.262

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.