Literature DB >> 17490882

Biomechanical comparison between CentraLoc and Intrafix fixation of quadrupled semitendinosus-gracilis allografts in cadaveric tibiae with low bone mineral density.

R Krupp1, J Nyland, C Smith, A Nawab, R Burden, D N M Caborn.   

Abstract

Supplementary or back-up tibial tunnel fixation of a quadruple semitendinosus-gracilis (STG) graft is often performed when the knee surgeon questions the integrity of intra-tunnel fixation. Back-up fixation devices such as staples however may contribute to increased knee pain and dysfunction. Both primary extra-tunnel and intra-tunnel fixation devices may provide sufficient quadruple STG graft fixation in a tibial tunnel to preclude the need for back-up fixation. This biomechanical study compared the fixation of quadruple STG allografts in standard drilled tunnels prepared in low apparent bone mineral density (BMD) cadaveric tibiae using either an Intrafix device with primary intra-tunnel fixation in a region of predominantly cancellous trabecular bone, or a CentraLoc device with primary extra-tunnel fixation in a region of predominantly cortical bone. The study hypothesis was that the CentraLoc device would display superior fixation in these low apparent BMD cadaveric tibiae. Matched pair tibiae and quadruple STG allografts were divided into two groups of seven specimens each. Extraction drilled tunnels matched allograft diameter. Constructs were pretensioned on a servo hydraulic device between 10 and 50 N for 10 cycles and isometric pretensioned at 50 N for 1 min prior to undergoing 500 loading cycles (50-250 N) and load to failure testing (20 mm/min). The CentraLoc group displayed superior load at failure (448.4+/-171 N vs. 338.4+/-119 N, P=0.04) and survived more loading cycles (410+/-154 cycles vs. 196+/-230 cycles, P=0.04) than the Intrafix group. Most CentraLoc group specimens (6/7, 85.7%) failed by device pullout with intact quadruple STG allograft strands while all Intrafix group specimens (7/7, 100%) failed by slippage of one or more strands (P=0.005).

Entities:  

Mesh:

Year:  2007        PMID: 17490882     DOI: 10.1016/j.knee.2007.04.001

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  3 in total

1.  The fixation strength of a novel ACL soft-tissue graft fixation device compared with conventional interference screws: a biomechanical study in vitro.

Authors:  Camilla Halewood; Michael T Hirschmann; Simon Newman; Jaffar Hleihil; Gershon Chaimski; Andrew A Amis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-09-14       Impact factor: 4.342

2.  Failure load of patellar tendon grafts at the femoral side: 10- versus 20-mm-bone blocks.

Authors:  Duncan E Meuffels; Marnix J N Niggebrugge; Jan A N Verhaar
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-10-07       Impact factor: 4.342

3.  Biomechanical evaluation of four femoral fixation configurations in a simulated anterior cruciate ligament replacement using a new generation of Ligament Advanced Reinforcement System (LARS™ AC).

Authors:  Olivier Barbier; Sandra Guérard; Philippe Boisrenoult; Patricia Thoreux
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-01-30
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.