| Literature DB >> 17487183 |
Sylva L Schwager1, Adriana K Carmona, Edward D Sturrock.
Abstract
Angiotensin I-converting enzyme (ACE) assays are commonly used for measuring enzymatic activity in clinical and biological samples. The fluorimetric procedure described is sensitive, rapid and involves unsophisticated procedures and inexpensive reagents. It uses the substrate hippuryl-L-histidyl-L-leucine, and the fluorescent adduct of the enzyme-catalyzed product L-histidyl-L-leucine is quantified fluorimetrically. This assay has been adapted for a 96-well plate format that produces comparable data to previously described assays and has the advantage of greater efficiency with respect to both time and reagents. The protocol can be used for routine purposes or for more detailed kinetic analyses. The apparent Km and kcat values for purified testis ACE determined from a double reciprocal plot were 3.0 mM and 195.7 s(-1), respectively. The protocol can be completed within 4 h.Entities:
Mesh:
Substances:
Year: 2006 PMID: 17487183 DOI: 10.1038/nprot.2006.305
Source DB: PubMed Journal: Nat Protoc ISSN: 1750-2799 Impact factor: 13.491