Vein graft anastomoses with magnets.

Christoph Heitmann1, Farah N Khan, Detlev Erdmann, Kevin C Olbrich, A Adam Sharkawy, Bruce Klitzman.   

Abstract

BACKGROUND: Performing vascular anastomoses requires complete circumferential access and is time-consuming and technically challenging. The purpose of our study was to assess a sutureless magnetic device for anastomosing vein grafts. METHODS AND
RESULTS: Oval magnets with a lumen were placed in six male foxhounds. The femoral artery was ligated and an 8 cm length of femoral vein was harvested and reversed. After a 4 mm venotomy or arteriotomy, one magnet was inserted into each vessel lumen and a second magnet was placed outside the vessel but aligned directly over the intraluminal magnet, forming a magnetic port in each vessel. The graft and target vessels were then allowed to self-align and seal, creating a side-to-side anastomosis. Patency was confirmed with duplex Doppler ultrasound scans after 6 and 13 weeks and during explantation after 14 weeks. At that time, the contralateral femoral vein was harvested and an acute graft was created as a control. Macroscopically there was no sign of stenoses or aneurysms. After explant, saline was perfused through all grafts and the hydrodynamic resistance was quantified. There was no significant difference in resistance between the acute and 14-week grafts indicating stenosis. Microscopic examination of 14-week anastomoses showed that all blood-contacting surfaces were well-endothelialised.
CONCLUSIONS: The magnetic vascular coupler allowed sutureless anastomoses between blood arteries and veins. This device might prove useful for anastomosis of large and small vessels, as well as for anastomosis or approximation of non-vascular structures such as peripheral nerves, fallopian tubes or ureters.

Entities:  

Mesh:

Year:  2007        PMID: 17481977     DOI: 10.1016/j.bjps.2006.10.017

Source DB:  PubMed          Journal:  J Plast Reconstr Aesthet Surg        ISSN: 1748-6815            Impact factor:   2.740


  2 in total

1.  Evaluation of a novel thermosensitive heparin-poloxamer hydrogel for improving vascular anastomosis quality and safety in a rabbit model.

Authors:  Ying-Zheng Zhao; Hai-Feng Lv; Cui-Tao Lu; Li-Juan Chen; Min Lin; Ming Zhang; Xi Jiang; Xiao-Tong Shen; Rong-Rong Jin; Jun Cai; Xin-Qiao Tian; Ho Lun Wong
Journal:  PLoS One       Date:  2013-08-27       Impact factor: 3.240

2.  The vascular connector, design of a new device for sutureless vascular anastomosis.

Authors:  Lulzim Vokrri; Xhavit Krasniqi; Arsim Qavdarbasha; Nexhmi Hyseni; Philippe Cinquin; Paolo Porcu; Carmine Sessa
Journal:  Ann Surg Innov Res       Date:  2014-11-22