Literature DB >> 17477833

An automated high throughput liquid chromatography-mass spectrometry process to assess the metabolic stability of drug candidates.

Dieter M Drexler1, James V Belcastro, Kenneth E Dickinson, Kurt J Edinger, Serhiy Y Hnatyshyn, Jonathan L Josephs, Robert A Langish, Colleen A McNaney, Kenneth S Santone, Petia A Shipkova, Adrienne A Tymiak, Tatyana A Zvyaga, Mark Sanders.   

Abstract

An automated high throughput process, termed the MetFast assay, is described to assess in vitro the general microsomal cytochrome P450 beta-nicotinamide adenine dinucleotide phosphate-mediated first-pass metabolic stability of potential drug candidates as a utility for pharmaceutical profiling. Utilizing robotic protocols with a multiprobe liquid handler, compounds are incubated with liver microsomes from different species. Samples are then analyzed by in-line liquid chromatography (LC)-mass spectrometry (MS) to determine the amount of compound remaining after a certain time, which allows calculation of metabolism rates. To quantitatively assess large numbers of structurally diverse compounds by LC-MS, a strategy based on an iterative two-step process was devised. Initially compounds are qualitatively analyzed by LC-ultraviolet (UV)/MS (step 1) to determine purity (UV detection) and structural integrity (MS detection). This step ensures that only correct and verified compounds with sufficient purity are being assayed to obtain reproducible high data quality. In addition, all necessary information is gathered to automatically generate specific quantitative methods for the subsequent bioanalytical analysis of metabolic stability samples by LC-UV/MS (step 2). In-house-developed, highly flexible and sophisticated data management software, termed SmartReport, is utilized for automated qualitative and quantitative LC-MS analysis set-up, data processing, and results reporting. The integration of key aspects, inherent "universal" collision-induced dissociation settings of ion trap mass spectrometers for tandem mass spectrometric scan functions utilized for compound-specific and sensitive quantitative MS methods, generic fast-LC conditions, generic MS instrument settings, and the functionality of SmartReport software resulted in an analytical process that routinely provides reproducible high-quality metabolic stability data on structurally diverse compounds. Described here is the setup of the MetFast assay, and metabolic stability data from assay validation compounds are given.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17477833     DOI: 10.1089/adt.2006.038

Source DB:  PubMed          Journal:  Assay Drug Dev Technol        ISSN: 1540-658X            Impact factor:   1.738


  4 in total

1.  Quantitative-qualitative data acquisition using a benchtop Orbitrap mass spectrometer.

Authors:  Kevin P Bateman; Markus Kellmann; Helmut Muenster; Robert Papp; Lester Taylor
Journal:  J Am Soc Mass Spectrom       Date:  2009-03-06       Impact factor: 3.109

2.  Development of proneurogenic, neuroprotective small molecules.

Authors:  Karen S MacMillan; Jacinth Naidoo; Jue Liang; Lisa Melito; Noelle S Williams; Lorraine Morlock; Paula J Huntington; Sandi Jo Estill; Jamie Longgood; Ginger L Becker; Steven L McKnight; Andrew A Pieper; Jef K De Brabander; Joseph M Ready
Journal:  J Am Chem Soc       Date:  2011-01-06       Impact factor: 15.419

3.  Allosteric inhibition of hypoxia inducible factor-2 with small molecules.

Authors:  Thomas H Scheuermann; Qiming Li; He-Wen Ma; Jason Key; Lei Zhang; Rui Chen; Joseph A Garcia; Jacinth Naidoo; Jamie Longgood; Doug E Frantz; Uttam K Tambar; Kevin H Gardner; Richard K Bruick
Journal:  Nat Chem Biol       Date:  2013-02-24       Impact factor: 15.040

4.  MRM screening/biomarker discovery with linear ion trap MS: a library of human cancer-specific peptides.

Authors:  Xu Yang; Iulia M Lazar
Journal:  BMC Cancer       Date:  2009-03-27       Impact factor: 4.430

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.