Fiber optic biosensor for the detection of C-reactive protein and the study of protein binding kinetics.

Chien Chou1, Hsien-Yeh Hsu, Hsieh-Ting Wu, Kai-Yu Tseng, Arthur Chiou, Chih-Jen Yu, Zheng-Yuan Lee, Tsu-Shin Chan.   

Abstract

Application of a fiber optic biosensor (FOB) to the real-time investigation of the interaction kinetics between FITC-conjugated monoclonal sheep anti-human C-reactive protein (CRP) antibody and CRP isoforms on the surface of optical fiber is described. Recently, both the native pentameric CRP (pCRP), an acute phase protein belonging to pentraxin family, and an isoform of pCRP, modified CRP (mCRP), have been suggested to have proinflammation effects on vascular cells in acute myocardial infarction (AMI). In current studies, we generate mCRP from pCRP, and use several methods including fluorescence spectral properties, circular dichroism, analytical ultracentrifuge, and Western blotting to demonstrate their differences in physical and chemical properties as well as the purity of pCRP and mCRP. In addition, we design and implement an FOB to study the real-time qualitative and quantitative biomolecular recognition of CRP isoforms. Specifically, the association and dissociation rate constants of the reaction between FITC-conjugated monoclonal sheep anti-human CRP antibody and the pCRP and mCRP are determined. The feasibility of our current approach to measure the association and dissociation rate constants of the reaction between tested CRP isoforms was successfully demonstrated.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17477740     DOI: 10.1117/1.2714029

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  4 in total

1.  A label-free fiber optic SPR biosensor for specific detection of C-reactive protein.

Authors:  Wenjia Wang; Zhigang Mai; Yuzhi Chen; Jiaqi Wang; Liang Li; Qingning Su; Xuejin Li; Xueming Hong
Journal:  Sci Rep       Date:  2017-12-04       Impact factor: 4.379

Review 2.  Sensors and Biosensors for C-Reactive Protein, Temperature and pH, and Their Applications for Monitoring Wound Healing: A Review.

Authors:  Pietro Salvo; Valentina Dini; Arno Kirchhain; Agata Janowska; Teresa Oranges; Andrea Chiricozzi; Tommaso Lomonaco; Fabio Di Francesco; Marco Romanelli
Journal:  Sensors (Basel)       Date:  2017-12-19       Impact factor: 3.576

Review 3.  Evaluation of Molecularly Imprinted Polymers for Point-of-Care Testing for Cardiovascular Disease.

Authors:  Brian Regan; Fiona Boyle; Richard O'Kennedy; David Collins
Journal:  Sensors (Basel)       Date:  2019-08-09       Impact factor: 3.576

4.  Analysis of Temperature-Jump Boundary Conditions on Heat Transfer for Heterogeneous Microfluidic Immunosensors.

Authors:  Fraj Echouchene; Thamraa Al-Shahrani; Hafedh Belmabrouk
Journal:  Sensors (Basel)       Date:  2021-05-18       Impact factor: 3.576