Grating interferometer based scanning setup for hard X-ray phase contrast imaging.

C Kottler1, F Pfeiffer, O Bunk, C Grünzweig, C David.   

Abstract

In x-ray radiography, particularly for technical and industrial applications, a scanning setup is very often favorable when compared to a direct two-dimensional image acquisition. Here, we report on an efficient scanning method for grating based x-ray phase contrast imaging with tube based sources. It uses multiple line detectors for staggered acquisition of the individual phase-stepping images. We find that the total exposure time does not exceed the time needed in an equivalent scanning setup for absorption radiography. Therefore, we conclude that it should be possible to implement the method into a scanning system without affecting the scanning speed or significant increase in cost but with the advantage of providing both the phase contrast and the absorption information at once.

Mesh:

Year:  2007        PMID: 17477673     DOI: 10.1063/1.2723064

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  18 in total

1.  Radiation dose efficiency comparison between differential phase contrast CT and conventional absorption CT.

Authors:  Joseph Zambelli; Nicholas Bevins; Zhihua Qi; Guang-Hong Chen
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

2.  Subspace-based resolution-enhancing image reconstruction method for few-view differential phase-contrast tomography.

Authors:  Huifeng Guan; Charlotte Klara Hagen; Alessandro Olivo; Mark A Anastasio
Journal:  J Med Imaging (Bellingham)       Date:  2018-06-28

3.  Fundamental relationship between the noise properties of grating-based differential phase contrast CT and absorption CT: theoretical framework using a cascaded system model and experimental validation.

Authors:  Ke Li; Nicholas Bevins; Joseph Zambelli; Guang-Hong Chen
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

4.  Comparison of data-acquisition designs for single-shot edge-illumination X-ray phase-contrast tomography.

Authors:  Yujia Chen; Weimin Zhou; Charlotte K Hagen; Alessandro Olivo; Mark A Anastasio
Journal:  Opt Express       Date:  2020-01-06       Impact factor: 3.894

5.  Helical X-ray phase-contrast computed tomography without phase stepping.

Authors:  M Marschner; M Willner; G Potdevin; A Fehringer; P B Noël; F Pfeiffer; J Herzen
Journal:  Sci Rep       Date:  2016-04-07       Impact factor: 4.379

6.  Asymmetric masks for laboratory-based X-ray phase-contrast imaging with edge illumination.

Authors:  Marco Endrizzi; Alberto Astolfo; Fabio A Vittoria; Thomas P Millard; Alessandro Olivo
Journal:  Sci Rep       Date:  2016-05-05       Impact factor: 4.379

7.  In-vivo X-ray Dark-Field Chest Radiography of a Pig.

Authors:  Lukas B Gromann; Fabio De Marco; Konstantin Willer; Peter B Noël; Kai Scherer; Bernhard Renger; Bernhard Gleich; Klaus Achterhold; Alexander A Fingerle; Daniela Muenzel; Sigrid Auweter; Katharina Hellbach; Maximilian Reiser; Andrea Baehr; Michaela Dmochewitz; Tobias J Schroeter; Frieder J Koch; Pascal Meyer; Danays Kunka; Juergen Mohr; Andre Yaroshenko; Hanns-Ingo Maack; Thomas Pralow; Hendrik van der Heijden; Roland Proksa; Thomas Koehler; Nataly Wieberneit; Karsten Rindt; Ernst J Rummeny; Franz Pfeiffer; Julia Herzen
Journal:  Sci Rep       Date:  2017-07-06       Impact factor: 4.379

8.  Laboratory-based X-ray phase-imaging scanner using Talbot-Lau interferometer for non-destructive testing.

Authors:  Shivaji Bachche; Masahiro Nonoguchi; Koichi Kato; Masashi Kageyama; Takafumi Koike; Masaru Kuribayashi; Atsushi Momose
Journal:  Sci Rep       Date:  2017-07-27       Impact factor: 4.379

9.  Correlation of image quality parameters with tube voltage in X-ray dark-field chest radiography: a phantom study.

Authors:  Andreas P Sauter; Jana Andrejewski; Manuela Frank; Konstantin Willer; Julia Herzen; Felix Meurer; Alexander A Fingerle; Markus R Makowski; Franz Pfeiffer; Daniela Pfeiffer
Journal:  Sci Rep       Date:  2021-07-08       Impact factor: 4.379

10.  Implementation of a Talbot-Lau interferometer in a clinical-like c-arm setup: A feasibility study.

Authors:  Florian Horn; Martino Leghissa; Sebastian Kaeppler; Georg Pelzer; Jens Rieger; Maria Seifert; Johannes Wandner; Thomas Weber; Thilo Michel; Christian Riess; Gisela Anton
Journal:  Sci Rep       Date:  2018-02-02       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.