Nondestructive and noncontact method for determining the spring constant of rectangular cantilevers.

Dmytro S Golovko1, Thomas Haschke, Wolfgang Wiechert, Elmar Bonaccurso.   

Abstract

We present here an experimental setup and suggest an extension to the long existing added-mass method for the calibration of the spring constant of atomic force microscope cantilevers. Instead of measuring the resonance frequency shift that results from attaching particles of known masses to the end of cantilevers, we load them with water microdrops generated by a commercial inkjet dispenser. Such a device is capable of generating drops, and thus masses, of extremely reproducible size. This makes it an ideal tool for calibration tasks. Moreover, the major advantage of water microdrops is that they allow for a nearly contactless calibration: no mechanical micromanipulation of particles on cantilevers is required, neither for their deposition nor for removal. After some seconds the water drop is completely evaporated, and no residues are left on the cantilever surface or tip. We present two variants: we vary the size of the drops and deposit them at the free end of the cantilever, or we keep the size of the drops constant and vary their position along the cantilever. For the second variant, we implemented also numerical simulations. Spring constants measured by this method are comparable to results obtained by the thermal noise method, as we demonstrate for six different cantilevers.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17477668     DOI: 10.1063/1.2720727

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  3 in total

Review 1.  Probing cellular microenvironments and tissue remodeling by atomic force microscopy.

Authors:  Thomas Ludwig; Robert Kirmse; Kate Poole; Ulrich S Schwarz
Journal:  Pflugers Arch       Date:  2007-12-06       Impact factor: 3.657

2.  A direct micropipette-based calibration method for atomic force microscope cantilevers.

Authors:  Baoyu Liu; Yan Yu; Da-Kang Yao; Jin-Yu Shao
Journal:  Rev Sci Instrum       Date:  2009-06       Impact factor: 1.523

3.  Characterization of the mechanical properties of qPlus sensors.

Authors:  Jan Berger; Martin Svec; Martin Müller; Martin Ledinský; Antonín Fejfar; Pavel Jelínek; Zsolt Majzik
Journal:  Beilstein J Nanotechnol       Date:  2013-01-02       Impact factor: 3.649

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.