Glass microfabricated nebulizer chip for mass spectrometry.

Ville Saarela1, Markus Haapala, Risto Kostiainen, Tapio Kotiaho, Sami Franssila.   

Abstract

A microfluidic nebulizer chip for mass spectrometry is presented. It is an all-glass device which consists of fusion bonded Pyrex wafers with embedded flow channels and a nozzle at the chip edge. A platinum heater is located on the wafer backside. Fabrication of the chip is detailed, especially glass deep etching, wafer bonding, and metal patterning. Various process combinations of bonding and metallization have been considered (anodic bonding vs. fusion bonding; heater inside/outside channel; metallization before/after bonding; platinum lift-off vs. etching). The chip vaporizes the liquid sample (0.1-10 microL min(-1)) and mixes it with a nebulizer gas (ca. 100 sccm N2). Operating temperatures can go up to 500 degrees C ensuring efficient vaporization. Thermal insulation of the glass ensures low temperatures at the far end of the chip, enabling easy interconnections.

Entities:  

Mesh:

Year:  2007        PMID: 17476387     DOI: 10.1039/b700101k

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  5 in total

1.  A practical guide for the fabrication of microfluidic devices using glass and silicon.

Authors:  Ciprian Iliescu; Hayden Taylor; Marioara Avram; Jianmin Miao; Sami Franssila
Journal:  Biomicrofluidics       Date:  2012-03-05       Impact factor: 2.800

2.  A Simple Method for Improving the Spatial Resolution in Infrared Laser Ablation Mass Spectrometry Imaging.

Authors:  Juha-Pekka Hieta; Anu Vaikkinen; Samuli Auno; Heikki Räikkönen; Markus Haapala; Gianmario Scotti; Jaakko Kopra; Petteri Piepponen; Tiina J Kauppila
Journal:  J Am Soc Mass Spectrom       Date:  2017-01-11       Impact factor: 3.109

3.  PHOTOLITHOGRAPHY-FREE LASER-PATTERNED HF ACID-RESISTANT CHROMIUM-POLYIMIDE MASK FOR RAPID FABRICATION OF MICROFLUIDIC SYSTEMS IN GLASS.

Authors:  Konstantin O Zamuruyev; Yuriy Zrodnikov; Cristina E Davis
Journal:  J Micromech Microeng       Date:  2016-10-28       Impact factor: 1.881

4.  Design, fabrication and test of a microfluidic nebulizer chip for desorption electrospray ionization mass spectrometry.

Authors:  A K Sen; J Darabi; D R Knapp
Journal:  Sens Actuators B Chem       Date:  2009-04-02       Impact factor: 7.460

5.  Chemical profiles of birch and alder bark by ambient mass spectrometry.

Authors:  Riikka-Marjaana Räsänen; Juha-Pekka Hieta; Juha Immanen; Kaisa Nieminen; Raisa Haavikko; Jari Yli-Kauhaluoma; Tiina J Kauppila
Journal:  Anal Bioanal Chem       Date:  2019-10-23       Impact factor: 4.142

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.