Literature DB >> 17474079

The rapid characterisation of poly(ethylene glycol) oligomers using desorption electrospray ionisation tandem mass spectrometry combined with novel product ion peak assignment software.

Jonathan P Williams1, Gillian R Hilton, Konstantinos Thalassinos, Anthony T Jackson, James H Scrivens.   

Abstract

A rapid method for the characterisation of polyglycol esters and ethers is described which uses accurate mass desorption electrospray ionisation (DESI) quadrupole time-of-flight mass spectrometry (Q-ToFMS). The results are combined with newly developed software which aids the interpretation of product ions produced using collision-induced dissociation (CID) of selected precursor ions. The poly(ethylene glycol) (PEG) samples analysed were PEG dibenzoate, PEG monooleate, PEG butyl ether, PEG bis(2-ethyl hexanoate) and PEG diacrylate. Lithium metal was used for cationisation of the PEG oligomers since it yielded the most useful structural information compared with other group I metals. The full scan mass spectra and product ion mass spectra were all obtained in <5 s. Interpretation of the MS/MS product ion spectra, using the product ion interpretation software which incorporates previously developed fragmentation rules, was carried out in <1 s.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17474079     DOI: 10.1002/rcm.3008

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  6 in total

1.  Transmission mode desorption electrospray ionization.

Authors:  Joseph E Chipuk; Jennifer S Brodbelt
Journal:  J Am Soc Mass Spectrom       Date:  2008-07-10       Impact factor: 3.109

2.  Reactive desorption electrospray ionization mass spectrometry (DESI-MS) of natural products of a marine alga.

Authors:  Leonard Nyadong; Edward G Hohenstein; Asiri Galhena; Amy L Lane; Julia Kubanek; C David Sherrill; Facundo M Fernández
Journal:  Anal Bioanal Chem       Date:  2009-03-07       Impact factor: 4.142

3.  High-throughput quantitative analysis by desorption electrospray ionization mass spectrometry.

Authors:  Nicholas E Manicke; Thomas Kistler; Demian R Ifa; R Graham Cooks; Zheng Ouyang
Journal:  J Am Soc Mass Spectrom       Date:  2008-11-01       Impact factor: 3.109

4.  The influence of material and mesh characteristics on transmission mode desorption electrospray ionization.

Authors:  Joseph E Chipuk; Jennifer S Brodbelt
Journal:  J Am Soc Mass Spectrom       Date:  2008-12-03       Impact factor: 3.109

5.  Ambient Characterization of Synthetic Fibers by Laser Ablation Electrospray Ionization Mass Spectrometry.

Authors:  Fred A M G van Geenen; Maurice C R Franssen; Anton H M Schotman; Han Zuilhof; Michel W F Nielen
Journal:  Anal Chem       Date:  2017-03-14       Impact factor: 6.986

6.  Combined use of direct analysis in real-time/Orbitrap mass spectrometry and micro-Raman spectroscopy for the comprehensive characterization of real explosive samples.

Authors:  Maxime C Bridoux; Adrián Schwarzenberg; Sébastien Schramm; Richard B Cole
Journal:  Anal Bioanal Chem       Date:  2016-06-18       Impact factor: 4.142

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.