Literature DB >> 17473402

Navigation in ACL reconstruction - comparison with conventional measurement tools.

D Kendoff1, R Meller, M Citak, A Pearle, S Marquardt, C Krettek, T Hüfner.   

Abstract

Restoration of rotational and translational stability is a goal of ACL reconstruction. Intraoperative instability measurements of AP translation and rotation are not well established clinically. We compared navigated measurements of tibial AP translation and rotation with mechanical measuring devices: the KT 1000 and a modified goniometer tool. Tests were repeated with intact and dissected ACLs, and measures of translation and rotation statistically compared. There was no significant difference in AP translation between navigation, 3.2 mm (range 1-6 mm) and the KT 1000, 4.8 mm (range, 4-7 mm) in our experimental set up (p>0.05). Tibial rotation revealed no significant difference, 0.12 degrees (range, 0 degrees -1 degrees ) between navigation and goniometer (p>0.05). Total range of rotation was 4.2 degrees (range, 2 degrees -6 degrees ) in intact and 7.05 degrees (range, 4 degrees -9 degrees ) in dissected ACLs (p<0.05). Stability parameters in ACL navigation can be measured precisely under laboratory conditions and results are not significantly different from mechanical testing devices.

Mesh:

Year:  2007        PMID: 17473402

Source DB:  PubMed          Journal:  Technol Health Care        ISSN: 0928-7329            Impact factor:   1.285


  5 in total

Review 1.  Dynamic knee laxity measurement devices.

Authors:  Mattias Ahldén; Yuichi Hoshino; Kristian Samuelsson; Paulo Araujo; Volker Musahl; Jón Karlsson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-12-31       Impact factor: 4.342

2.  Open wedge valgus tibial osteotomies: affecting the distinct ACL bundles.

Authors:  Daniel Kendoff; Dimitrios Koulalis; Mustafa Citak; James Voos; Andrew D Pearle
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-02-11       Impact factor: 4.342

Review 3.  Biomechanical techniques to evaluate tibial rotation. A systematic review.

Authors:  Mak-Ham Lam; Daniel Tik-Pui Fong; Patrick Shu-Hang Yung; Kai-Ming Chan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-09-13       Impact factor: 4.342

4.  Femoral Aperture Fixation Improves Anterior Cruciate Ligament Graft Function When Added to Cortical Suspensory Fixation: An In Vivo Computer Navigation Study.

Authors:  Mark D Porter; Bruce Shadbolt
Journal:  Orthop J Sports Med       Date:  2016-09-07

Review 5.  Current use of navigation system in ACL surgery: a historical review.

Authors:  S Zaffagnini; F Urrizola; C Signorelli; A Grassi; T Roberti Di Sarsina; G A Lucidi; G M Marcheggiani Muccioli; T Bonanzinga; M Marcacci
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-10-15       Impact factor: 4.342

  5 in total