Literature DB >> 17473042

Microleakage of self-etch primer/adhesives in endodontically treated teeth.

Deniz Korasli1, Fatmagül Ziraman, Perihan Ozyurt, S Burcak Cehreli.   

Abstract

BACKGROUND: The authors evaluated the coronal marginal leakage of endodontically treated teeth bonded with four self-etching adhesives and one total-etch adhesive system.
MATERIALS AND METHODS: The investigators prepared Class II cavities in 60 extracted human premolars. They performed conventional endodontic therapy using a resin-based sealer and gutta-percha points. They randomly assigned each tooth to a group receiving one of the following adhesives: Adper Prompt L-Pop (3M ESPE, Seefeld, Germany), Clearfil SE Bond (Kuraray, Osaka, Japan), FL Bond (Shofu, Kyoto, Japan), Single Bond (3M ESPE) or Xeno III (Dentsply De Trey, Konstanz, Germany). They restored all teeth with resin-based composite material (Z250, 3M ESPE). Specimens underwent thermocycling and dye penetration and were sectioned longitudinally. The authors photographed the sections under a stereomicroscope. They transferred the images to an IBM-compatible personal computer for quantitative assessment of dye penetration using image analysis software. They analyzed data by means of Kruskal-Wallis and Mann-Whitney U tests (P = .05) and evaluated two specimens from each group under scanning electron microscopy.
RESULTS: None of the tested self-etch adhesives completely eliminated microleakage. Dye leakage was restricted to the coronal cavity walls; it did not migrate toward the pulp chamber or toward the root canal. Single Bond and Clearfil SE Bond showed significantly lower dye penetration values at occlusal and gingival margins.
CONCLUSIONS: The coronal sealing performance of the tested self-etch adhesive systems in endodontically treated teeth was material-dependent. The use of Clearfil SE Bond in such teeth can help achieve a marginal seal comparable to that achieved with Single Bond.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17473042     DOI: 10.14219/jada.archive.2007.0235

Source DB:  PubMed          Journal:  J Am Dent Assoc        ISSN: 0002-8177            Impact factor:   3.634


  6 in total

1.  Fracture resistance of endodontically treated teeth restored with a bulkfill flowable material and a resin composite.

Authors:  Almira Isufi; Gianluca Plotino; Nicola Maria Grande; Pietro Ioppolo; Luca Testarelli; Rossella Bedini; Dina Al-Sudani; Gianluca Gambarini
Journal:  Ann Stomatol (Roma)       Date:  2016-07-19

2.  Bonding effects of cleaning protocols and time-point of acid etching on dentin impregnated with endodontic sealer.

Authors:  Tatiane Miranda Manzoli; Joissi Ferrari Zaniboni; João Felipe Besegato; Flávia Angélica Guiotti; Andréa Abi Rached Dantas; Milton Carlos Kuga
Journal:  Restor Dent Endod       Date:  2022-04-06

3.  Microleakage evaluation of adhesive systems following pulp chamber irrigation with sodium hypochlorite.

Authors:  Mohammad Javad Moghaddas; Horieh Moosavi; Marjaneh Ghavamnasiri
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2014-03-05

4.  Resin composite repair: Quantitative microleakage evaluation of resin-resin and resin-tooth interfaces with different surface treatments.

Authors:  Cigdem Celik; Sevi Burcak Cehreli; Neslihan Arhun
Journal:  Eur J Dent       Date:  2015 Jan-Mar

5.  Root canal adaptation and intra-tubular penetration of three fiber-post cementation systems.

Authors:  Carmen Llena; María García-Gallart; Leopoldo Forner; Marco Ferrari
Journal:  J Clin Exp Dent       Date:  2018-12-01

6.  Comparison of three adhesive systems in class II composite restorations in endodontically treated teeth: Influence of Er:YAG laser conditioning and gingival margin levels on microleakage.

Authors:  Emel-Olga Onay; Kivanc Yamanel; Yonca Korkmaz-Ceyhan; Kamran Gulsahi
Journal:  J Clin Exp Dent       Date:  2018-08-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.